Endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS) is increasingly used to manage failed endoscopic biliary drainage in patients with malignant biliary obstruction [ 1 ] [ 2 ] [ 3 ]. A recent study showed that, for EUS-HGS, a stent ≥ 3 cm in length in the luminal portion may be suitable to prevent stent migration and achieve long-term stent patency [ 4 ]. However, such a placement can sometimes make re-intervention difficult. Here, we describe a novel re-intervention technique for HGS stent occlusion. A 75-year-old man with advanced pancreatic cancer presented with a recurrence of jaundice 11 months after undergoing EUS-HGS using a covered metal stent (Niti-S Biliary Covered Stent; 8 × 100 mm; Taewoong Medical, Seoul, Korea) for distal malignant biliary obstruction ([ Fig. 1 a ]). Computed tomography (CT) revealed a dilated intrahepatic and extrahepatic bile duct ([ Fig.1 b ]), and gastroscopy confirmed stent occlusion ([ Fig. 2 ]). Re-intervention was attempted via the HGS route; however, insertion of an endoscopic retrograde cholangiopancreatography (ERCP) catheter into the intrahepatic bile duct through the proximal end of the HGS stent failed. Fig. 1 Computed tomography (CT) images showing: a a covered metal stent deployed between the left intrahepatic bile duct and the stomach; b a dilated intrahepatic bile duct. Fig. 2 Gastroscopy showing the occluded metal stent. The length of stent in the gastric lumen was about 5 cm. Re-intervention through the stent mesh was then attempted. A 0.025-inch stiff guidewire was inserted, penetrating the stent cover membrane close to the gastric puncture site ([ Fig. 3 ]). Next, a 6-mm fine-gauge balloon catheter (REN; 3-Fr tip; Kaneka Medix, Osaka, Japan) was inserted into the bile duct, breaking through and opening the stent cover membrane. After successfully advancing the guidewire through the distal biliary stricture into the duodenum, an additional metal stent (BileRush selective; 10 × 60 mm, 5.7-Fr delivery system; Piolax, Kanagawa, Japan) was inserted through the mesh of the HGS stent to cover the biliary stricture in an antegrade fashion ([ Fig. 4 ]; [ Video 1 ]). Fig. 3 A 0.025-inch stiff guidewire was inserted to penetrate the stent cover membrane near the gastric puncture site. Fig. 4 An additional uncovered metal stent with a fine-gauge delivery system that was inserted to cover the distal biliary stricture in an antegrade fashion through the mesh of the previously deployed stent: a in endoscopic view; b on fluoroscopy. Quality: mobile 360 480 720 Download An additional metal stent was deployed through the mesh of the previously placed hepaticogastrostomy (HGS) stent to cover the malignant distal biliary stricture in an antegrade fashion as treatment for HGS stent occlusion. The postoperative period was uneventful and the patient’s jaundice resolved in a few days. This “through-the-mesh” technique is simple and safe, and could be a useful re-intervention option after EUS-HGS. Endoscopy_UCTN_Code_CPL_1AL_2AD
No takes yet. Share an insight, caveat, or question.
Minaga et al. (2016) studied this question.