The H atom lifetime in a low pressure hydrogen microwave plasma was measured using a pulse induced fluorescence technique. This technique is compared to results obtained by a laser spectroscopy technique. We first demonstrate the validity of the method and then deduce H atom lifetime pressure dependence. The H atom surface loss probability on fused silica was also deduced from our measurements. We show that this coefficient is not constant in the time afterglow but decreases almost by one order of magnitude (from 2.3×10−3 to 2.1×10−4) during the first milliseconds. These results are explained using recent experimental and theoretical works concerning atom-surface interaction in low temperature plasmas.
No takes yet. Share an insight, caveat, or question.
Rousseau et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: