BACKGROUND: Positron emission tomography using the [18F] fluoride metabolite combined with computerized tomography (F-PET/CT) can be used to analyze the metabolic status of the periprosthetic bone after surgery for total hip arthroplasty. METHODS: To obtain normal PET referent values, 44 patients with 5 models of well-functioning hip prosthetic components were analyzed by F-PET/CT, radiography, and clinical score. Another group of patients having painful total hip arthroplasty, but whose radiography showed no conclusive signs of loosening, was analyzed by F-PET/CT scans before revision surgery. RESULTS: < .01) for the referent group having the same stem model. At revision surgery, the stems in the painful group were assessed to be loose. At 2-year follow-up, the revised patients were all pain free. CONCLUSION: F-PET/CT may be a new diagnostic tool for assessing occult loose stems that are not seen by radiography.
No takes yet. Share an insight, caveat, or question.
Gösta Ullmark (2020) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: