Key result
ICD recipients linked to ~89% higher MACE risk vs. pacemakers, mediated by lower follow-up adherence.
Why the study?
Whether consensus-recommended follow-up mediates cardiovascular outcome disparities between ICD and PPM recipients was unknown.
Does implantable cardioverter defibrillator (ICD) versus permanent pacemaker (PPM) placement affect cardiovascular outcomes, and is this disparity mediated by consensus-recommended follow-up adherence?
Cohort (n=6,806)
Yes
Does implantable cardioverter defibrillator (ICD) versus permanent pacemaker (PPM) placement affect cardiovascular outcomes, and is this disparity mediated by consensus-recommended follow-up adherence?
More than half of the excess cardiovascular risk in ICD recipients compared to pacemaker recipients is statistically mediated by suboptimal adherence to consensus-recommended follow-up, identifying a potentially modifiable pathway to improve outcomes.
BACKGROUND: Consensus-recommended follow-up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown. METHODS: We prospectively studied 6806 patients undergoing CIED implantation across a multi-hospital system (2019-2023; median follow-up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow-up mediated components, adjusting for demographics and comorbidities. RESULTS: ICD recipients had significantly lower consensus-recommended follow-up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40-0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66-2.25, p < 0.001), of which 53.5% was mediated by follow-up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24-0.38), with only 7.9% mediated by follow-up adherence. CONCLUSIONS: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow-up adherence-a potentially modifiable pathway. These findings identify follow-up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high-risk CIED populations.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) conducted a cohort in Cardiac implantable electronic device (CIED) recipients (n=6,806). Implantable cardioverter defibrillator (ICD) vs. Permanent pacemaker (PPM) was evaluated on Major adverse cardiovascular events (MACE) (HR 1.89, 95% CI 1.66-2.25, p=<0.001). ICD recipients had a higher MACE risk than pacemaker recipients (HR 1.89; 95% CI 1.66-2.25; P<0.001), with 53.5% of this excess risk statistically mediated by lower follow-up adherence.