Key result
Absorb bioresorbable scaffold shows no difference in 2-year MACE vs. EES in diabetic patients.
Why the study?
There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds at a 2-year horizon.
Cohort (n=1,097)
Yes
Answers are grounded in this paper and cite their sources.
Similar MACE rates with Absorb BVS in diabetics support further study; leaves open randomized confirmation before clinical consideration.
OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES.
No takes yet. Share an insight, caveat, or question.
Campos et al. (2017) conducted a cohort in Diabetes mellitus requiring stent implantation (n=1,097). Absorb bioresorbable vascular scaffold (Absorb BVS) vs. Everolimus-eluting metal stents (EES; XIENCE V) was evaluated on Ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR) (p=0.40). Treatment with the Absorb bioresorbable vascular scaffold yielded similar 2-year ischemia-driven MACE rates compared to everolimus-eluting stents in diabetic patients (6.5% vs. 8.9%; P=0.40).
Synapse has enriched 10 related papers. Consider them for comparative context: