Answers are grounded in this paper and cite their sources.
PRECIS: This longitudinal case series provides valuable long-term data on the safety and efficacy of iStent inject with concomitant cataract surgery. Patients experienced significant and durable reductions in both intraocular pressure (IOP) and medication burden through 3 years postoperative. PURPOSE: The purpose of this study was to examine the 3-year effectiveness and safety of iStent inject second-generation trabecular micro-bypass stent implantation with concomitant phacoemulsification cataract surgery in eyes with various glaucoma subtypes and severities. METHODS: This was a single-center consecutive case series. Three-year outcomes included mean IOP and medications, the proportions of eyes with IOP ≤18, ≤15, and ≤12 mm Hg, and success (absence of secondary glaucoma interventions). Safety included best-corrected visual acuity (BCVA), cup-to-disc ratio, visual field (VF) mean deviation, retinal nerve fiber layer (RNFL), and ganglion cell-inner plexiform layer (GCIPL) thickness, and adverse events. RESULTS: A total of 124 eyes with different glaucoma subtypes and severities were included. At 3 years postoperative, mean IOP reduced from 16.90±3.85 mm Hg preoperatively to 13.17±2.83 mm Hg (22% reduction, P<0.001) and mean medication burden decreased from 2.38±1.29 medications preoperatively to 1.16±1.22 medications (51% reduction, P<0.001). At 3 years, 96% of eyes achieved IOP ≤18 mm Hg (vs. 69% preoperatively), 80% of eyes achieved IOP ≤15 mm Hg (vs. 40% preoperatively), and 42% of eyes achieved IOP ≤12 mm Hg (vs. 7% preoperatively) with 76% of eyes eliminating ≥1 medication and 37% of eyes eliminating ≥2 medications versus preoperative medication burden. The 3-year cumulative survival rate was 74%. Postphacoemulsification BCVA improvement was preserved, and cup-to-disc ratio, VF mean deviation, and RNFL and GCIPL thickness remained stable. A favorable safety profile included no intraoperative complications and few, transient, postoperative adverse events. CONCLUSION: Significant and sustained IOP and medication reductions were achieved through 3 years after iStent inject implantation with cataract surgery in a real-world clinical population with mild-to-severe glaucoma, along with favorable safety including stable BCVA, VF, and RNFL and GCIPL thickness.
No takes yet. Share an insight, caveat, or question.
Salimi et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: