The feasibility of using the E-pulse technique to diagnose changes in the properties of simple layered materials is undertaken. Numerical results for a conductor-backed lossy slab and a Salisbury screen show that changes in permittivity, conductivity and thickness can be diagnosed in the presence of white Gaussian noise.
No takes yet. Share an insight, caveat, or question.
Stenholm et al. (2003) studied this question.