Case Report (n=1)
A structured sequence of neo-ostium creation and balloon crush is a reproducible and effective strategy for performing TAVR in patients with protruding ostial coronary stents.
Successful strut wiring enabled TAVR despite protruding ostial stent; leaves open generalizability and safety in larger cohorts.
BACKGROUND: Protruding ostial stents represent a unique hazard for transcatheter aortic valve replacement (TAVR). CASE SUMMARY: An 81-year-old woman with symptomatic severe aortic stenosis and recent right coronary artery stenting with a 10-mm segment protruding into the aortic root presented for TAVR evaluation. After multidisciplinary discussion, the decision was made to proceed with TAVR with stent modification. The right coronary artery was wired through the stent struts at the distal end of the protruded segment and was ballooned, creating a neo-ostium. The protruded segment was crushed against the aortic wall using a valvuloplasty balloon. A balloon-expandable TAVR valve was deployed, with no coronary obstruction. DISCUSSION: This case represents a challenging TAVR procedure requiring a unique strategy to modify a protruding stent. TAKE-HOME MESSAGES: A structured sequence of: 1) neo-ostium creation (displacement of protruding stent segment); 2) balloon aortic valvuloplasty crush (aortic wall alignment); 3) controlled TAVR valve deployment; and 4) ostial optimization is reproducible.
No takes yet. Share an insight, caveat, or question.
Iyengar et al. (2026) conducted a case report in Symptomatic severe aortic stenosis with protruding right coronary artery stent (n=1). TAVR with structured stent modification was evaluated on Coronary obstruction. TAVR with structured stent modification successfully deployed a valve without coronary obstruction in an 81-year-old woman with a 10-mm protruding right coronary artery stent.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: