Submicron aerosols are difficult to collect electrostatically, motivating passive upstream conditioning that shifts particles toward more readily captured size ranges. This study presents a controlled, geometry-resolved experimental comparison linking rib-induced flow structures, NaCl aerosol size redistribution, and downstream electrostatic collection. Eight confined-channel rib configurations were evaluated under identical operating conditions using planar particle image velocimetry and size-resolved number measurements with the electrostatic precipitator deactivated and activated. Rib geometry governed flow separation, recirculation, transverse motion, and turbulence intensity. The zig-zag configuration without a center gap produced the strongest coupled recirculation and transverse interaction and the clearest redistribution signature: depletion of 0.3–0.8 μm particles accompanied by enrichment near 1.1 μm. Peak local turbulence intensity alone did not predict performance; coherent recirculation and transverse transport were more informative. With electrostatic activation, this best-performing geometry increased the collection efficiency of 0.3 μm aerosols from approximately 15% in the smooth channel to nearly 50%. These results establish an experimental link between rib-resolved flow organization, apparent size redistribution, and enhanced submicron aerosol collection.