Answers are grounded in this paper and cite their sources.
This ex vivo study aimed to evaluate the material-dependent effects of a high metal artifact reduction (MAR) algorithm on quantitative cone-beam computed tomography (CBCT) image-quality parameters assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Nine dental material conditions—an amalgam restoration, composite restoration, glass ionomer cement restoration, metal crown, orthodontic bracket, root canal filling material, calcium hydroxide [Ca(OH)₂] medicament, implant body, and implant abutment—together with one intact control tooth were evaluated in ten separate dry human mandibles. Each condition was represented by a single specimen. A total of ten CBCT acquisitions were performed using a single CBCT unit and a standardized acquisition protocol. Each acquisition was reconstructed without MAR and with high MAR, resulting in 20 reconstructed CBCT image datasets. Image analysis was performed using ImageJ2/Fiji. SNR and CNR were calculated from standardized regions of interest placed adjacent to the evaluated materials without including the materials themselves. The significance level was set at p < 0.05. MAR application produced statistically significant changes in the SNR adjacent to most materials ( p < 0.001). SNR values generally increased with high MAR, whereas a significant reduction was observed adjacent to the metal crown ( p < 0.001). No significant SNR change was detected adjacent to the root canal filling material ( p > 0.05). High MAR significantly increased CNR values adjacent to the metal crown, orthodontic bracket, composite restoration, and implant abutment ( p < 0.001), whereas CNR significantly decreased adjacent to the amalgam restoration and implant body ( p < 0.05) and the glass ionomer cement restoration ( p = 0.047). No significant CNR differences were observed for the root canal filling material, calcium hydroxide [Ca(OH)₂] medicament, or control tooth ( p > 0.05). Within the limitations of this exploratory ex vivo study, the effect of high MAR on quantitative image-quality parameters, as assessed using SNR and CNR, varied according to the type of dental material. Because each material condition was represented by a single specimen, the findings should be interpreted cautiously. The results are specific to the CBCT unit, acquisition protocol, and high-MAR setting used in this study. Further studies including multiple independent specimens and observer-based diagnostic assessments are required to determine whether these quantitative changes influence diagnostic performance.
No takes yet. Share an insight, caveat, or question.
Korkmaz et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: