A new charge pump power-factor-correction (CPPFC) electronic ballast with a wide range of line input voltage is proposed in this paper. Circuit derivation and DC-bus voltage stress at start-up mode are discussed. The average lamp current control with switching frequency modulation is developed to achieve constant lamp power operation and low-crest factor. The proposed CPPFC electronic ballast is analyzed, implemented, and evaluated. It features continuous line input current, low total harmonic distortion (THD), constant lamp power operation, low-crest factor, and less switching current stress with low-DC-bus voltage stress for the line voltages from 180 to 265 V.