Key result
Male sex was associated with greater right coronary cusp geometric height (difference 2.9 mm) compared to females, but this difference was no longer significant after body surface area adjustment.
Why the study?
Aortic valve geometric indices vary with body size and are important for valve repair planning, but detailed 3D TEE data indexed to BSA are limited.
null
Cross-Sectional (n=63)
No
null
Mean Difference: 2.9 (95% CI 1.7–4)
p-value: p=<0.001
Significant sex-based differences in 3D TEE-derived tricuspid aortic valve geometries are largely attenuated after adjusting for body surface area.
BSA adjustment attenuates sex differences in aortic cusp height; supports indexing for body size in valve geometry assessment and extends population variation data.
Background Aortic valve geometry is a key parameter for aortic valve repair, which serves as a surgical alternative to valve replacement for aortic insufficiency treatment. Individuals with different body sizes may exhibit varying geometric parameters of the aortic valve. This study aims to provide a detailed assessment of normal aortic valve geometric indices and their relationship to body surface area (BSA) using three-dimensional transesophageal echocardiography (3D TEE), addressing limitations of standard transthoracic echocardiography data and aiding in predicting the feasibility of valve repair and guiding appropriate patient selection. Methods In this cross-sectional analytical study, sixty-three patients with structurally normal tricuspid aortic valves undergoing TEE for non-aortic-valve indications were enrolled. Comprehensive 3D TEE of aortic valve was performed and evaluated. Results The mean BSA was 1.85 ± 0.20 m². The mean maximal aortic annular diameter was 22.30 ± 3.36 mm, and the mean annular perimeter was 69.59 ± 8.31 mm. The left coronary cusp had the greatest GH (16.5 mm), while the right coronary cusp had the greatest EH (8.47 mm). In crude comparisons, males had greater RCC GH than females (difference, 2.9 mm; 95% CI, 1.7–4.0; p < 0.001), greater LCC GH (difference, 2.0 mm; 95% CI, 0.92–3.1; p < 0.001), and greater RCC EH (difference, 1.3 mm; 95% CI, 0.51–2.2; p = 0.002). After BSA indexing, these differences were no longer statistically significant for RCC GH (p = 0.129), LCC GH (p = 0.917), or RCC EH (p = 0.332). However, BSA-indexed LVOT area and aortic annular area remained significantly greater in males (p = 0.005 and p = 0.016, respectively). Inter-observer ICCs ranged from 0.84 to 0.92, and intra-observer ICCs from 0.89 to 0.95. Conclusion Significant sex-based differences in aortic valve geometries are attenuated after BSA adjustment. Moreover, comparison with previous studies suggests that variations in aortic valve parameters across populations are likely attributable to differences in BSA. The measurements presented in this study should be considered exploratory 3D TEE-derived reference data rather than definitive normative values and require validation in larger, multicenter cohorts.
No takes yet. Share an insight, caveat, or question.
Sahebjam et al. (2026) conducted a cross-sectional in Structurally normal tricuspid aortic valves (n=63). Male sex vs. Female sex was evaluated on Right coronary cusp geometric height (unadjusted difference) (MD 2.9 mm, 95% CI 1.7-4.0, p=<0.001). Male sex was associated with greater right coronary cusp geometric height (difference 2.9 mm) compared to females, but this difference was no longer significant after body surface area adjustment.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: