In this work, the morphological, structural, and electrical properties of Ti/Al/W contacts to p-type implanted silicon carbide (4H-SiC) have been monitored as a function of the annealing temperature (800–1100 °C). The increase of the annealing temperature induces a transition from a rectifying to an Ohmic behavior, with a specific contact resistance of 5.8 × 10−4 Ωcm2. The electrical behavior has been correlated with the morphological and structural analyses. In particular, the transition to an Ohmic behavior was accompanied by a gradual increase of the surface roughness and by the occurrence of a reaction leading to the formation of new phases in the stack and at the interface (TiAl3, W(SiAl)2, and TiC). The presence of Al-rich protrusions penetrating in the SiC substrate was also observed. From the temperature dependence of the electrical parameters, a barrier height of 0.69 eV for this system was determined. The thermal stability of the contacts has been demonstrated for long-term (up to 100 h) thermal cycling at 400 °C.
No takes yet. Share an insight, caveat, or question.
Vivona et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: