Why the study?
Alternans and rotating spiral waves are both important precursors of cardiac arrhythmias, but their relationship is not well understood.
Alternans, a beat-to-beat temporal alternation in the sequence of heartbeats, is a known precursor of the development of cardiac fibrillation, leading to sudden cardiac death. The equally important precursor of cardiac arrhythmias is the rotating spiral wave of electro-mechanical activity, or reentry, on the heart tissue. Here, we show that these two seemingly different phenomena can have a remarkable relationship. In well controlled in vitro tissue cultures, isotropic populations of rat ventricular myocytes sustaining a temporal rhythm of alternans can support period-2 oscillatory reentries and vice versa. These reentries bear "line defects" across which the phase of local excitation slips rather abruptly by 2pi, when a full period-2 cycle of alternans completes in 4pi. In other words, the cells belonging to the line defects are period-1 oscillatory, whereas all of the others in the bulk medium are period-2 oscillatory. We also find that a slowly rotating line defect results in a quasi-periodic like oscillation in the bulk medium. Some key features of these phenomena can be well reproduced in computer simulations of a nonlinear reaction-diffusion model.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2007) studied Cardiac alternans and reentries (in vitro). In vitro observation and computer simulation was evaluated on Relationship between temporal alternans and rotating spiral wave reentries.