Background: Automated brain-MRI analysis is usually judged by accuracy at a single operating point, yet a model that is accurate on average may still fail without signalling that it is about to fail. Selective prediction addresses this by allowing a model to abstain, but the resulting trade-off between coverage and risk is rarely quantified in medical imaging. Objective: This study asks whether confidence- and entropy-based selective prediction produces a measurable reduction in selective risk in a biomedical vision–language classifier by concentrating errors among withheld cases, and at what coverage cost. Three further components of a brain-MRI-analysis framework—volumetric segmentation, glioma grading and structured report generation—are evaluated as complementary evidence about the reliability profiles of different modules, not as independent contributions. Methods: A LoRA-fine-tuned LLaVA-Med classifier was evaluated on the 1000-image BRISC2025 test partition, with a disjunctive rejection rule based on softmax confidence and predictive entropy. Volumetric segmentation used nnU-Net v2 (3D full-resolution) on BraTS2020 with a three-fold ensemble evaluated on 74 held-out cases; glioma grading (high- versus low-grade) used DenseNet121 on multi-slice representations; report generation used Meta Llama 3.2 3B Instruct fine-tuned with QLoRA on structured findings. All proportions are reported with 95% Wilson score intervals under a single analysis plan documented before the reported analyses were finalised. Results: Withholding 1.80% of predictions (95% CI 1.14–2.83) raised selective accuracy to 97.76% (95% CI 96.63–98.52) and reduced selective risk from 3.40% to 2.24%, a relative reduction of 34.1%. Withheld predictions were strongly enriched for errors (66.7% versus 2.24%; odds ratio 87.3, Fisher exact p = 4.6 × 10−15), capturing 35.3% of all errors while issuing 99.38% of the predictions that were correct. Considered as a detector of its own errors, the rule has a balanced accuracy of 67.34%; this describes the binary rejection decision at the realised threshold and does not identify the AUROC of the underlying continuous score, which the single operating point leaves anywhere in [0.351, 0.996]. Because the per-sample probability vectors were not retained, the full risk–coverage curve, the rule ablations and calibration error could not be computed, and the thresholds (τc = 0.6, τH = 1.0) were selected empirically on an undocumented partition; the selective-prediction finding is therefore reported as a single-operating-point case study and is exploratory. Among the complementary components, three-fold ensembling improved held-out mean Dice from 0.7948 to 0.8150 (+0.0202), reported descriptively because the per-case values needed for a paired test were not preserved. Glioma grading did not achieve better-than-chance discrimination: balanced accuracy 49.91%, Cohen’s κ −0.0023, Matthews correlation coefficient −0.0026, low-grade recall 8.96% (95% CI 5.81–13.57), and accuracy (74.03%) below a constant majority-class classifier (79.46%); the associated McNemar statistic is reported descriptively because slice-level observations are not independent. Report generation produced high automatic similarity scores (BERTScore F1 0.9513) that are not interpretable without baselines. Conclusions: Confidence- and entropy-based abstention produced a measurable reduction in selective risk at low rejection rates, and it did so because errors concentrated among the cases were withheld by the confidence/entropy rule rather than because predictions were discarded indiscriminately. At the realised coverage the rule captured 65.5% (95% bootstrap CI 41.9–87.8) of the reduction achievable by an oracle that rejects only true errors. The component-wise comparison shows that this reliability behaviour cannot be assumed for every module: high aggregate accuracy and useful discrimination came apart in the grading task. These findings are component-wise and do not constitute an end-to-end, externally validated or clinically validated pipeline. The vision–language evaluation is at image level: BRISC2025 carries no patient identifiers, so patient-level independence cannot be established and the reported intervals should be read with that constraint in mind.
No takes yet. Share an insight, caveat, or question.
Hala Alshamlan (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: