Key result
Extended phase mapping eliminates false detections and resolves missed cardiac rotations across preclinical and clinical datasets.
Why the study?
Conventional phase mapping methods assume continuous cardiac phase maps, causing ill-defined phase indices and errors in detecting rotational electrical activity in regions with phase defects.
Does extended phase mapping improve the detection accuracy of rotational drivers in cardiac arrhythmias compared to conventional phase mapping?
Does extended phase mapping improve the detection accuracy of rotational drivers in cardiac arrhythmias compared to conventional phase mapping?
Extended phase mapping addresses limitations of conventional methods by accounting for phase defects, leading to more accurate and physiologically consistent identification of rotational electrical activity in arrhythmias.
Phase defects may cause false rotational driver detections in arrhythmia mapping; extends phase mapping methods but clinical validation is needed.
Phase mapping is a widespread method for identifying rotational electrical activity sustaining cardiac arrhythmias. However, conventional implementations assume that the cardiac phase map is continuous, leading to ill-defined phase indices in regions affected by functional conduction block, fibrosis, or anatomical boundaries. These regions of discontinuous or undefined phase, termed phase defects, lead to both false positive and false negative detections of rotational drivers. This work introduces an improved phase mapping implementation termed extended phase mapping that explicitly detects and accounts for phase defects, enabling robust calculation of the phase index around them. Extended phase mapping is applied to (1) simulated excitation patterns using the Fenton–Karma model, (2) experimental optical mapping data of rat ventricular fibrillation, and (3) a clinical CARTO activation map of atrial tachycardia. Across all datasets, the extended approach eliminates erroneous detections and resolves previously missed rotations. Our results demonstrate that proper treatment of phase defects yields a unified and physiologically consistent characterization of all rotational drivers including near-complete and anatomical reentries. Therefore, we propose that explicitly accounting for phase defects, rather than tracking singular points alone, gives a more complete and consistent characterization of rotational dynamics in cardiac tissue.
No takes yet. Share an insight, caveat, or question.
Verstraeten et al. (2026) studied Cardiac arrhythmias. Extended phase mapping vs. Conventional phase mapping was evaluated on Detection of rotational drivers. Extended phase mapping explicitly accounted for phase defects, eliminating erroneous detections and resolving previously missed rotations across simulated, experimental, and clinical datasets.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: