Deep learning models for kidney stone classification on CT frequently report accuracies above 98%, but many are trained on augmented datasets split at the image level, allowing near-duplicate copies of the same slice to appear in both training and test sets. To quantify how much this leakage inflates reported performance, we reassessed a deep learning slice-level classifier under a leakage-free, patient-wise protocol with calibration, uncertainty quantification and cross-center validation, using a multi-center CT dataset of 3,364 original and 35,457 augmented images from 201 patients across three centers. This study proposes no new architecture; its contribution is the quantification and benchmarking of an evaluation effect. Patients were partitioned so that all their images, including augmentations, stayed within a single split, and validation and test sets contained only original images. A hybrid CNN-Transformer classifier was trained alongside matched comparator models on one identical training budget, then retrained under a random image-level split to isolate the effect of leakage, with additional analyses including cross-validation, ten-seed repetition, leave-one-hospital-out testing, temperature scaling, conformal prediction, examination-level aggregation and saliency mapping. Under the patient-wise protocol the classifier achieved an AUC of 0.971, accuracy of 0.962, sensitivity of 0.953, specificity of 0.981 and a Matthews correlation coefficient of 0.914, with patient-level cluster bootstrap intervals; the leaky image-level split raised accuracy to 0.990 and AUC to 0.999. Across ten seeds the mean inflation was 5.0 accuracy points (95% CI 2.7 to 7.3; paired t test P = 0.0009) and 2.7 AUC points (95% CI 1.4 to 3.9; P = 0.001), present in every seed. A plain ResNet-18 reached a numerically higher AUC than the hybrid model with no significant difference detected, and equivalence was not established; a convolution-free Transformer performed near chance (AUC 0.569). Performance fell on held-out centers. Calibration and selective classification improved reliability, and no sex disparity in sensitivity was found once results were pooled across patients at the patient level. Because the analysis uses eight-bit rendered images without Hounsfield unit information, it is a methodological proof of concept rather than an evaluation of a deployable system. These findings show that image-level splitting substantially overstates real-world performance, and that patient-wise, calibrated evaluation offers a more trustworthy basis for appraisal.
No takes yet. Share an insight, caveat, or question.
Obeten et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: