Key result
Cerebral embolic protection during TAVR linked to ~68% lower risk of early ischemic stroke.
Why the study?
The clinical significance of cerebral embolic protection devices during transfemoral TAVR remains under debate regarding their impact on periprocedural neurological outcomes.
Does routine use of cerebral embolic protection reduce early periprocedural ischemic stroke in patients undergoing transfemoral transcatheter aortic valve replacement?
Cohort (n=1,101)
No
Does routine use of cerebral embolic protection reduce early periprocedural ischemic stroke in patients undergoing transfemoral transcatheter aortic valve replacement?
Hazard Ratio: 0.32 (95% CI 0.14–0.74)
Absolute Event Rate: 1.4% vs 4.1%
p-value: p=0.007
Routine use of cerebral embolic protection during transfemoral TAVR in an intermediate-to-high risk population is associated with a significantly reduced incidence of early periprocedural clinical ischemic stroke.
Objective Cerebral Embolic Protection Devices (CEPs) have been designed to minimize the risk of periprocedural stroke. The clinical significance of these devices, however, is still under debate. Aims We aimed to compare periprocedural neurological outcomes and mortality in patients undergoing transfemoral transcatheter aortic valve replacement (TF-TAVR) with versus without CEP. Methods A single-center retrospective analysis of 1101 patients undergoing transfemoral TAVR from August 2017 to May 2025 was performed. CEPs were used routinely at our institution whenever feasible beginning with October 2019. The primary outcome was defined as the incidence of ischemic stroke occurring within 3 days postoperatively. Secondary endpoints included overall neurological outcomes defined as a combined endpoint of stroke, transient ischemic attack (TIA) and delirium within 3 days and short-term all-cause mortality. Results Overall, 809 underwent TF-TAVR with CEP, while 292 were treated without. The primary endpoint of clinical ischemic stroke occurred less frequently in the CEP group (1.4% vs. 4.1%), and the group difference revealed a significant result in a univariable Cox regression analysis (p = 0.007). No clinically relevant differences were observed in the incidence of TIA (0.5% vs. 0.7%, p = 0.71) and postprocedural delirium (1.6% vs. 2.4%, p = 0.39). Although the 30-day mortality rate in the control group was higher, the difference did not reach statistical significance (3.9% vs. 1.9%, p = 0.06). Conclusions The use of neuroprotection during TAVR was associated with a reduced early periprocedural ischemic stroke.
No takes yet. Share an insight, caveat, or question.
Baysal et al. (2026) conducted a cohort in Severe aortic stenosis requiring transfemoral transcatheter aortic valve replacement (TAVR) (n=1,101). Cerebral embolic protection (CEP) device (Sentinel or TriGuard 3) vs. Transfemoral TAVR without cerebral embolic protection was evaluated on Incidence of clinical ischemic stroke occurring within 3 days postoperatively (HR 0.32, 95% CI 0.14-0.74, p=0.007). The use of cerebral embolic protection during transfemoral TAVR was associated with a significantly reduced risk of early periprocedural ischemic stroke compared to no protection (1.4% vs. 4.1%, HR 0.32).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: