The neutron capture cross sections and capture γ-ray spectra of 143,145,146Nd were measured in the neutron energy region of 10 to 90 keV and at 550 keV. A neutron time-of-flight method was adopted with a 1.5-ns pulsed neutron source by the 7Li(p, n)7Be reaction and with a large anti-Compton NaI(Tl) γ-ray spectrometer. A pulse-height weighting technique was applied to observed capture γ-ray pulse-height spectra to derive capture yields. The capture cross sections were obtained with the error of about 5% by using the standard capture cross sections of 197Au. The evaluated values of JENDL-3.2 and previous measurements were compared with the present results. The capture γ-ray spectra were obtained by unfolding the observed capture γ-ray pulse-height spectra. An anomalous shoulder was observed around 2 MeV in the γ-ray spectra of 145,146Nd, and the energy position of the shoulder was consistent with the systematics obtained in our previous work.
No takes yet. Share an insight, caveat, or question.
Veerapaspong et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: