Key result
3D-TEE shows secundum ASD area changes by ~61% through the cardiac cycle.
Why the study?
The dynamic contraction pattern and determinants of secundum atrial septal defect morphology through the cardiac cycle were not well defined by three dimensional echocardiography.
Observational (n=50)
p-value: p=< 0.0001
May support 3D echo for dynamic ASD assessment; leaves open whether transthoracic imaging suffices clinically.
OBJECTIVE: To define by three dimensional echocardiography the pattern and potential determinants of contraction of a secundum atrial septal defect through the cardiac cycle, and to evaluate the possibility of using cross sectional transthoracic and transoesophageal imaging to assess the dynamic nature of the defect. DESIGN: Three dimensional echocardiography was performed using a multiplane transoesophageal probe on 50 patients with a secundum atrial septal defect (median age 9.8 years). Nine patients were excluded because of poor images or morphological features that precluded defect measurement. In 41 cases, defect area, long and short axis length, and distance of the attenuated anterior rim were measured in their largest and smallest dimensions. RESULTS: Defect area changed significantly through the cardiac cycle (mean change 61%, p < 0.0001; range 17% to 86%). The defect contracted symmetrically and was not related to patient age, defect size, heart rate, Qp/Qs ratio, the presence of an aneurysmal atrial septum, or attenuated anterior rim. In all cases with an attenuated anterior rim (n = 13), the length of the rim significantly decreased (p = 0. 001) during atrial systole. Dynamic changes measured by either transthoracic or transoesophageal cross sectional images did not correlate with those obtained by three dimensional imaging. CONCLUSIONS: Three dimensional echocardiography shows dynamic features of defects in the atrial septum. This information may lead to an improved understanding of the pathophysiology of atrial shunting.
No takes yet. Share an insight, caveat, or question.
Maeno et al. (2000) conducted an observational in Secundum atrial septal defect (n=50). Three dimensional transoesophageal echocardiography vs. Cross sectional transthoracic and transoesophageal imaging was evaluated on Change in defect area through the cardiac cycle (p=< 0.0001). Three dimensional transoesophageal echocardiography demonstrated that secundum atrial septal defect area changed significantly through the cardiac cycle (mean change 61%, p < 0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: