Researchers increasingly propose data-driven prediction models for non-invasive fibrosis assessment in metabolic dysfunction-associated steatotic liver disease (MASLD).However, strong predictive performance alone does not show whether a model performs better than Fibrosis-4 Index (FIB-4), a simple and widely used fibrosis score based on routinely available clinical data.This review evaluated whether prediction models provide greater diagnostic discrimination than FIB-4 when both are assessed in the same patients for advanced fibrosis (≥F3).PubMed, Europe PMC, OpenAlex, and Semantic Scholar were searched for studies evaluating prediction models and conventional non-invasive fibrosis tests in adults with MASLD, MASH, NAFLD, or NASH.Eligible head-to-head comparisons required the model and FIB-4 to be evaluated in the same cohort for the same ≥F3 endpoint with verifiable test-specific areas under the receiver operating characteristic curve (AUROCs).We used automation-based screening and quantitative validation, followed by full-text verification, targeted evidence recovery, and final cohort-level adjudication.Separate-cohort biopsy-validation evidence formed the primary analysis, while internal holdout evidence was included secondarily.The effect measure was the within-study difference in AUROC (ΔAUROC), pooled using random-effects restricted maximum likelihood with Hartung-Knapp confidence intervals (CIs).Of 23,420 deduplicated records, 2,892 reports were assessed for eligibility, and 44 potential same-cohort comparisons were identified.Final verification produced three eligible head-to-head studies.The primary separatecohort evidence comprised two studies, with study-level ΔAUROCs of 0.053 and 0.140, respectively.The pooled primary ΔAUROC was 0.086 (95% Hartung-Knapp CI -0.448 to 0.621).Adding the internal holdout study, which reported a ΔAUROC of 0.165, increased the pooled estimate to 0.126 (95% CI -0.023 to 0.276).All three point estimates were positive, but both pooled CIs included no difference.A 500-record reference assessment of automated exclusions identified no false negatives, corresponding to a negative predictive value of 100.0%(95% CI 99.2%-100.0%).The available head-to-head evidence is too sparse and imprecise to establish that prediction models outperform FIB-4.Moreover, all included evaluations were conducted by the original model-development teams rather than by independent third-party investigators.The findings should therefore be considered preliminary and do not support replacing FIB-4.Future studies should prioritise third-party multicentre validation, calibration, clinically actionable thresholds, and direct assessment of net clinical benefit.
No takes yet. Share an insight, caveat, or question.
Bukhari et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: