Background: It remains unclear whether physiological load affects fencing accuracy to the same extent as movement speed and whether a shortened protocol can reproduce the outcomes of a full repeated-sprint protocol. Methods: Ten fencers (foil/épée; 7 men, 3 women; 16–30 years) completed anthropometric, handgrip strength, and maximal heart rate assessments on Day 1; a target-hitting task at baseline and at 50% and 85% of maximal heart rate using two fencing gestures on Day 2; and ten 16 m shuttles (4–2–4–2–4 m), separated by 8 s of recovery and each ending with a lunge to a graded target, on Day 3. Results: Shuttle time increased non-linearly, reaching an estimated maximum at shuttle 7.27 (95% CI: 6.15–11.34), whereas no significant trend in touch performance was detected across shuttles (p = 0.988). On Day 2, accuracy did not differ across heart rate conditions but differed between gestures (p < 0.001). On Day 3, heart rate reached 84.60–93.45% of maximal heart rate. The seven-shuttle fatigue index showed close agreement with the full-protocol index (ICC = 0.96; limits of agreement: −2.58 to 1.25), indicating reproducibility rather than criterion validity. Conclusions: Performance fatigability was expressed as slower movement, with no detectable decline in touch accuracy; the underlying physiological or neuromuscular mechanisms were not assessed. Seven shuttles emerged as a candidate protocol length, which requires test-retest reliability and independent validation before it can replace the full protocol.
No takes yet. Share an insight, caveat, or question.
Colombo et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: