A pilot-scale Power-to-Gas plant powered by hybrid wind-solar energy and equipped with a 2.4 kW anion exchange membrane (AEM) electrolyzer provided the experimental basis for this work. The electrolyzer delivered 250 NL h−1 of oxygen at 0.5 barg and 55°C, yielding 7.28 kg of O2 over 24 h, all previously vented. An Oxygen Recovery System (O2RS) comprising a 50 L buffer, a pneumatic booster, and a 100 L tank pressurized to 35 barg was designed and simulated minute-by-minute across the full cycle. The simulation predicts 99.95% recovery (7 273 g, 3.4 g relieved), a 26.2-fold volume reduction from 4 100 to 156.5 L, and a stored density of 46.5 kg m−3; the tank reaches 35 barg after 14 h 29 min and retains 2 701 g as next-day inventory. Useful isentropic work of 54.2 W against 517.3 W of compressor demand gives 10.55 kWh day−1, a 21.6% overhead on the 48.93 kWh day−1 electrolyzer load and a specific recovery cost of 1.45 kWh kg−1 O2. Hybrid generation covered 38.8% of the 59.47 kWh daily demand; restricting operation to surplus hours reached 100% renewable energy coverage at 41.8% lower yield. These figures position the O2RS as a technically viable pathway for transforming a residual byproduct into a storable resource within renewable hydrogen systems. Physical validation of the proposed design is identified as future experimental work.
No takes yet. Share an insight, caveat, or question.
Noriega et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: