Key result
Preoperative fever is linked to ~2.6-fold higher odds of positive valve cultures in endocarditis surgery.
Why the study?
Positive valve cultures in patients undergoing cardiac surgery for infective endocarditis have been associated with higher in-hospital mortality, but risk factors and outcome relations remain unclear.
Does a positive valve culture in patients undergoing cardiac surgery for infective endocarditis predict one-year mortality or relapse?
Cohort (n=345)
No
Does a positive valve culture in patients undergoing cardiac surgery for infective endocarditis predict one-year mortality or relapse?
Hazard Ratio: 0.99 (95% CI 0.46–2.1)
Absolute Event Rate: 14% vs 13%
p-value: p=0.97
While positive valve cultures during surgery for infective endocarditis correlate with shorter preoperative antibiotics, preoperative fever, and staphylococcal infections, they do not predict increased 1-year mortality or relapse.
Positive valve cultures do not predict one-year mortality or relapse after IE surgery; leaves open their role in risk stratification or guiding therapy.
Introduction Cardiac surgery is required in up to half of the patients with infective endocarditis (IE). Positive valve cultures have been associated with higher in-hospital mortality. The aims were to identify risk factors for positive valve cultures and its relation to outcome.Methods Patients subjected to heart valve cultures due to surgery for IE in Skåne University Hospital, Lund, between 2012 and 2021 were identified through microbiology records. Risk factors for positive valve cultures and information on mortality and relapse were retrieved through medical records. Univariable and multivariable logistic regressions were performed.Results A total of 345 episodes with IE in 337 patients subjected to cardiac surgery were included and valve cultures were positive in 78 (23%) episodes. In multivariable logistic regression, preoperative fever (adjusted odds ratio (AOR) 2.6, 95% confidence interval (CI) 1.2–5.6, p = 0.02), prosthetic heart valve (AOR 3.3, CI 1.4–7.9, p = 0.01), a single affected valve (AOR 4.8, CI 1.2–20, p = 0.03), blood culture findings of S. aureus, enterococci, or coagulase negative staphylococci compared to viridans streptococci (AOR 20–48, p < 0.001), and a shorter duration of antibiotic treatment (p < 0.001), were associated to positive valve culture. One-year mortality was 13% and a relapse was identified in 2.5% of episodes. No association between positive valve cultures and one-year mortality or relapse was identified.Conclusions Positive valve cultures were associated to short preoperative antibiotic treatment, IE caused by staphylococci, preoperative fever and prosthetic valve but not to relapse or mortality.
No takes yet. Share an insight, caveat, or question.
Sunnerhagen et al. (2023) conducted a cohort in Infective endocarditis requiring cardiac surgery (n=345). Positive valve culture vs. Negative valve culture was evaluated on One-year mortality (HR 0.99, 95% CI 0.46-2.1, p=0.97). Positive valve cultures were associated with short preoperative antibiotic treatment, staphylococci, preoperative fever, and prosthetic valves, but did not increase the risk of one-year mortality (HR 0.99) or relapse.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: