Key result
Transjugular transcatheter mitral repair successfully reduces mitral regurgitation to mild without 6-month complications.
Why the study?
Procedural experience with right internal jugular vein access for transcatheter edge-to-edge mitral valve repair after failed transfemoral access remains limited.
Can transcatheter edge-to-edge mitral valve repair be successfully performed via the right internal jugular vein when transfemoral access is not feasible?
Case Report (n=1)
Can transcatheter edge-to-edge mitral valve repair be successfully performed via the right internal jugular vein when transfemoral access is not feasible?
Right internal jugular venous access is a feasible and safe alternative for transcatheter edge-to-edge mitral valve repair when conventional transfemoral access is precluded by severe vascular tortuosity.
May enable TEER via jugular access when femoral route unavailable; leaves open need for systematic safety and efficacy data.
Background Transcatheter edge-to-edge repair of the mitral valve is conventionally performed via transfemoral venous access. When this route is not feasible, the right internal jugular vein may provide an alternative, but procedural experience remains limited. Case Summary A 93-year-old woman with refractory heart failure had atrial functional mitral regurgitation and low-flow, low-gradient aortic stenosis. After transcatheter aortic valve implantation, moderate-to-severe mitral regurgitation persisted. Transfemoral edge-to-edge repair was unsuccessful because severe iliac venous tortuosity prevented adequate catheter control. The procedure was subsequently performed via the right internal jugular vein using the MitraClip G4 system. A pre-existing iatrogenic atrial septal defect was reused, and temporary left ventricular apical wire support facilitated advancement of the steerable guiding catheter into the left atrium. Stepwise + knob rotation increased height and working space, improved the markedly under-straddled configuration, and permitted further advancement of the clip delivery system. Subsequent M- and P-knob adjustments achieved an appropriate trajectory towards A2/P2, with an S-shaped fluoroscopic configuration. Leaflet grasping reduced mitral regurgitation to mild without access-site complications. Mild mitral regurgitation was maintained at 6 months without heart-failure rehospitalization. Discussion Right internal jugular access may be a feasible alternative when transfemoral access is not possible. Successful navigation requires recognition of access-specific catheter behaviour and adaptation of steering under real-time fluoroscopy and transoesophageal echocardiography. An S-shaped fluoroscopic configuration may serve as a practical landmark of a favourable trajectory towards the mitral valve.
No takes yet. Share an insight, caveat, or question.
Konami et al. (2026) conducted a case report in Atrial functional mitral regurgitation and refractory heart failure (n=1). Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system was evaluated on Reduction in mitral regurgitation and heart-failure rehospitalization. Transcatheter edge-to-edge mitral valve repair via the right internal jugular vein successfully reduced mitral regurgitation to mild without complications or heart-failure rehospitalization at 6 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: