Key result
Percutaneous gooseneck snare safely retrieves embolized tricuspid repair device, avoiding surgery and enabling prompt discharge.
Why the study?
Complete intraprocedural detachment with embolization of a tricuspid edge-to-edge repair device is rare, and percutaneous retrieval has been reported only exceptionally.
Case Report (n=1)
Percutaneous retrieval of an embolized tricuspid edge-to-edge repair device using a gooseneck snare is a feasible management strategy in high-risk patients when complete detachment occurs.
May inform bailout strategies for clip embolization in tricuspid TEER; hypothesis-generating pending multicenter validation.
Background and Clinical Significance: Tricuspid transcatheter edge-to-edge repair (T-TEER) is an established therapy for severe tricuspid regurgitation (TR) in selected patients. Single-leaflet device attachment (SLDA) is the commonest device-related complication, but complete intraprocedural detachment with embolization is rare, and percutaneous retrieval of an embolized tricuspid device has been reported only exceptionally. Case Presentation: An inoperable elderly patient with previous transcatheter aortic valve implantation (TAVI) and torrential functional TR underwent T-TEER. After implantation of the first clip at the anteroseptal commissure with apparently adequate leaflet capture, anterior SLDA was identified and progressed to complete detachment and right atrial embolization of the device. Despite this, the T-TEER was completed by successful implantation of the second clip, leaving only mild residual central TR. In the same session, the embolized device was retrieved percutaneously from the femoral venous system using a 15 mm gooseneck snare advanced through a 22 Fr sheath, with a safety wire and en-bloc removal, without forcing ensheathing and without venous injury. The patient was discharged on post-procedure day 2 with durable TR reduction and clinical improvement. Conclusions: Complete leaflet detachment is a possible complication of T-TEER. Confirming deep, symmetric insertion in multiple echocardiographic windows before every release is essential. When embolization occurs, knowledge of device dimensions and immediate availability of a complete snare kit is important. Although this approach may be considered in selected patients, particularly those at high surgical risk, the available evidence is limited to isolated case reports and does not allow general conclusions on its safety or efficacy.
No takes yet. Share an insight, caveat, or question.
Matetić et al. (2026) conducted a case report in Severe tricuspid regurgitation (n=1). Tricuspid transcatheter edge-to-edge repair (T-TEER) and percutaneous device retrieval was evaluated. Percutaneous retrieval of an embolized tricuspid edge-to-edge repair device was successfully performed using a 15 mm gooseneck snare, allowing patient discharge on post-procedure day 2.