Key result
Tapered LVOT morphology is linked to ~2.6-fold higher risk of permanent pacemaker implantation after TAVR.
Why the study?
Conduction defects requiring permanent pacemaker implantation after TAVR with self-expanding prostheses are common but not universally permanent, and predictors of persistent device dependency are unclear.
Cohort (n=276)
No
INTRODUCTION: A common complication of transcatheter aortic valve repair (TAVR) is development of conduction defects requiring pacemaker (PPM) implantation. These defects are not universally permanent. OBJECTIVE: To determine the incidence and predictors of persistent device dependency in patients with PPM implantation following TAVR with a self-expanding prosthesis. METHODS: Records of patients who underwent post-TAVR PPM implantation were reviewed. Patients with persistent complete AV block (AVBIII) one month post-TAVR were compared to those regaining conduction. RESULTS: Between September 2014 and March 2017, 485 patients underwent TAVR with a self-expanding prosthesis; 77 (15.9%) underwent PPM implantation for AVBIII. Device interrogation at one month was available for 61 patients (79%): 22 (36.1%) had resolution of AVBIII while 39 (63.9%) remained pacemaker-dependent. Pre-TAVR right bundle branch block was more frequent in device-dependent patients (19 of 38, 50% vs 4 of 22, 18%; RR 2.75; P = .01). Device-dependence was associated with AVBIII as the first postprocedural rhythm (37 of 39, 95% vs 12 of 22, 55%; RR 1.74; P < .0001), earlier implantation (median 1d, IQR: 0-1.5d vs 2d, IQR: 1.0-4.0d, P = .0004), and a shorter duration of hospitalization (median 3d, IQR: 2-3.5d vs 4d, IQR: 2-5.75d, P = .03). Pacemaker dependence was also associated with a higher prosthesis-to left ventricular outflow tract (LVOT) diameter (1.45 ± 0.11 vs 1.39 ± 0.07; P = .02) and the lack of prior aortic valvuloplasty (5 of 39, 13% vs 8 of 22, 36%; RR 0.35; P = .03). CONCLUSIONS: In patients receiving a PPM following self-expanding TAVR, a long-term pacing requirement can be predicted from the timing of AV block, existing conduction-system disease, larger prosthesis-to-LVOT diameter, and the lack of aortic valvuloplasty.
No takes yet. Share an insight, caveat, or question.
Lader et al. (2019) conducted a cohort in Severe Aortic Stenosis requiring TAVR (n=276). Tapered left ventricular outflow tract (LVOT) shape vs. Nontapered LVOT shape (tubular or flared) was evaluated on Permanent pacemaker implantation (PPI) following TAVR (HR 2.6, 95% CI 1.2-5.7, p=0.014). A tapered left ventricular outflow tract morphology was independently associated with an increased risk of permanent pacemaker implantation following transcatheter aortic valve replacement (HR 2.6, 95% CI 1.2-5.7, P=0.014).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: