Liquid-phase sensing characteristics of open-gate AlGaN∕GaN high electron mobility transistor (HEMT) structures were investigated in aqueous solutions and polar liquids. In de-ionized water, the open-gate HEMT clearly showed good drain I-V characteristics with current saturation and pinch-off behavior, very similar to I-V characteristics of typical Schottky-gate HEMTs. We observed a fine parallel shift in the transfer curves according to change in the pH value in a solution, indicating the corresponding potential change at the AlGaN surface. The sensitivity for the potential change was 57.5mV∕pH, very close to the theoretical value of 58.9mV∕pH at 24°C for the Nernstian response to H+ ions. In the low drain bias region, the drain current linearly decreased with the pH value. This also indicated a systematic potential change at the AlGaN surface due to pH change. The present open-gate device showed a fast response to the pH change and a stable operation at fixed pH values. A possible mechanism for the pH response of the AlGaN surface is discussed in terms of equilibrium reactions of hydroxyls at the AlGaN surface with H+ in a solution. It was also found that the device was quite sensitive to changes in the electrostatic boundary conditions of the open-gate area by exposure to polar liquids. The drain current linearly decreased with increasing normalized liquid dipole moment.
No takes yet. Share an insight, caveat, or question.
Kokawa et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: