OBJECTIVE: This research aimed to compare, through traction tests, eight types of superelastic and heat-activated NiTi archwires, by six trade companies (GAC, TP, Ormco, Masel, Morelli and Unitek) to those with addition of copper (CuNiTi 27°C and 35°C, Ormco). METHODS: The tests were performed in an EMIC mechanical testing machine, model DL10000, capacity of 10 tons, at the Military Institute of Engineering (IME). RESULTS: The results showed that, generally, heat-activated NiTi archwires presented slighter deactivation loadings in relation to the superelastic ones. Among the archwires that presented deactivation loadings biologically more adequate are the heat-activated by GAC and by Unitek. Among the superelastic NiTi, the CuNiTi 27°C by Ormco were the ones that presented slighter deactivation loadings, being statistically (ANOVA) similar to the ones presented by the heat-activated NiTi archwires from Unitek. When compared the CuNiTi 27°C and 35°C archwires, it was observed that the 27°C presented deactivation forces of, nearly, ⅓ of the presented by the 35°C. CONCLUSIONS: It was concluded that the CuNiTi 35°C archwires presented deactivation loadings biologically less favorable in relation to the other heat-activated NiTi archwires, associated to lower percentage of deformation, on the constant baselines of deactivation, showing less adequate mechanical behavior under traction, in relation to the other archwires.