This paper presents the method of a six-degree-of-freedom (DOF) posture measurement in a linear stage by employing a single unit of an optical encoder. The proposed optical encoder was constructed to simultaneously measure the posture along the traveling axis; angular errors, pitch, yaw and roll; and translational errors, Δ X , Δ Y and Δ Z . It consists of a diffractive optical element, a corner cube, four separate two-dimensional position-sensitive detectors, four photodiodes and auxiliary optics components. The circularly polarizing interferometric technique was integrated to measure the displacement of the stage along the traveling axis in a robust manner and the resolution was estimated to be less than 0.4 nm. Two types of stages were employed for the measurement implementation, the piezoelectric transducer-driven and the ballscrew-driven, and they were feedback-controlled for the traveling axis, respectively. With a single travel of the stage, it provided a six-DOF motion error with a high resolution, less than 0.03 arcsec, 20 nm and 0.4 nm for angular errors, Δ Y and Δ Z , and Δ X , respectively, at the same time. As a result, it was seen that motion errors of the stage have relevance to the driving mechanism and the whole construction of the stage.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: