Key result
RVOT leadless pacemaker placement is linked to ~52% lower cardiomyopathy incidence versus mid-septal implants.
Why the study?
Leadless ventricular pacemakers provide only RV pacing and may cause pacing-induced cardiomyopathy, yet it was unclear whether implant site or atrioventricular synchronous pacing using the Micra AV device influences cardiomyopathy occurrence and LVEF evolution.
Does implant site (RVOT vs mid-septal) or atrioventricular synchronous pacing (Micra AV vs VR) influence the incidence of cardiomyopathy and LVEF evolution in patients undergoing ventricular leadless pacemaker implantation?
Observational (n=401)
No
Does implant site (RVOT vs mid-septal) or atrioventricular synchronous pacing (Micra AV vs VR) influence the incidence of cardiomyopathy and LVEF evolution in patients undergoing ventricular leadless pacemaker implantation?
In patients receiving ventricular leadless pacemakers, right ventricular outflow tract (RVOT) implantation is associated with a significantly lower risk of cardiomyopathy and slower LVEF decline compared to mid-septal implantation, whereas Micra AV device use alone does not reduce cardiomyopathy incidence.
RVOT implantation may lower cardiomyopathy risk with leadless pacemakers; leaves open confirmation in randomized trials.
Background Leadless ventricular pacemakers (LPM) provide only RV pacing, which may lead to pacing-induced cardiomyopathy (PICM). It is unclear whether LPM implant site or atrioventricular synchronous pacing using the Micra AV device influence PICM occurrence. Objective To evaluate the incidence of cardiomyopathy after LPM implantation and explore the association of implant site and AV-synchronous pacing with cardiomyopathy risk and LVEF evolution. Methods This single-center retrospective study included 401 patients implanted with an LPM (Micra AV n=145) between July 2015 and March 2025. PICM was defined as cardiomyopathy (≥10% LVEF decline to <50%) in the presence of >20% ventricular pacing, where pacing was considered the primary cause. Risk factors for cardiomyopathy and LVEF evolution were assessed using Cox regression and mixed-effects modelling. Results Over a median follow-up of 33.0 months, all-cause cardiomyopathy occurred in 13.6% (4.8%/year), while PICM was identified in 5.5% (1.9%/year). RVOT implantation was independently associated with a lower incidence of all-cause cardiomyopathy (HR 0.48, P=0.019), and a slower LVEF decline (-0.56%/year vs -1.43%/year, P=0.013) compared with mid-septal implantation. Device type (Micra AV vs VR) was not associated with clinical outcomes or LVEF evolution. Among patients developing cardiomyopathy, 92.7% were medically treated, with 57.9% achieving ≥10% LVEF improvement, and 36.8% complete recovery. CRT upgrade was uncommon (7.3%). Conclusion Cardiomyopathy occurred in a substantial proportion of LPM recipients. RVOT implantation was associated with lower cardiomyopathy incidence and slower LVEF decline, whereas Micra AV implantation did not improve clinical outcomes. However, higher AV synchrony was linked to slower LVEF deterioration.
No takes yet. Share an insight, caveat, or question.
Weyenbergh et al. (2026) conducted an observational in Cardiomyopathy after ventricular leadless pacemaker implantation (n=401). Right ventricular outflow tract (RVOT) leadless pacemaker implantation vs. Mid-septal implantation was evaluated on All-cause cardiomyopathy (≥10% LVEF decline to <50%) (HR 0.48, p=0.019). RVOT leadless pacemaker implantation was associated with a lower incidence of all-cause cardiomyopathy compared with mid-septal implantation (HR 0.48, P=0.019).