Key result
Robotic mitral valve repair yields comparable 4-year survival and MR recurrence vs nonrobotic repair.
Why the study?
The study aimed to directly compare the early and midterm surgical outcomes of robotic versus nonrobotic minimally invasive mitral valve repair.
Does robotic minimally invasive mitral valve repair improve early and midterm surgical outcomes compared to nonrobotic minimally invasive mitral valve repair in patients undergoing mitral valve repair?
Cohort (n=422)
Does robotic minimally invasive mitral valve repair improve early and midterm surgical outcomes compared to nonrobotic minimally invasive mitral valve repair in patients undergoing mitral valve repair?
Robotic minimally invasive mitral valve repair achieves comparable perioperative and 4-year survival and valve durability outcomes to nonrobotic approaches, despite longer cardiopulmonary bypass times, increased blood transfusion requirements, and longer ICU stays.
Supports robotic mitral repair as viable alternative in experienced centers; leaves open need for RCTs to confirm broader safety and efficacy.
Objective: To compare the surgical outcomes of nonrobotic and robotic minimally invasive mitral valve repair. Methods: We retrospectively reviewed patients who underwent minimally invasive mitral valve repair from January 2014 to March 2024. After excluding the learning curve cases, early and midterm outcomes were compared. Results: A total of 422 patients who underwent minimally invasive mitral valve repair (nonrobotic, n = 103; robotic, n = 319) were enrolled. The robotic group had a higher EuroSCORE II ( P < 0.001). After propensity matching, the final cohort included 84 and 168 patients in each group. In the robotic group after matching, concomitant procedures remained significantly more frequent ( P = 0.030). However, operative time ( P = 0.782) and cross-clamping time ( P = 0.452) were comparable, whereas cardiopulmonary bypass time was significantly longer in the robotic group ( P = 0.031). Postoperative blood transfusion ( P < 0.001), chest tube output within 24 h ( P < 0.001), and intensive care unit stay ( P = 0.042) remained higher in the robotic group after matching. Postoperative mitral regurgitation was no greater than mild in both groups ( P = 0.146). At 4 years, overall survival was 94.4% versus 98.4% ( P = 0.215), and freedom from recurrence of moderate or greater mitral regurgitation was 98.5% versus 97.9% ( P = 0.230) after matching. These results are consistent with those observed before matching. Conclusions: Robotic mitral valve repair demonstrated comparable perioperative and midterm outcomes despite greater transfusion requirements and a higher frequency of concomitant procedures. The higher rate of concomitant procedures should be interpreted with caution because it may partly reflect differences in surgical era and patient selection.
No takes yet. Share an insight, caveat, or question.
Nakamae et al. (2026) conducted a cohort in Mitral valve disease requiring mitral valve repair (n=422). Robotic minimally invasive mitral valve repair vs. Nonrobotic minimally invasive mitral valve repair was evaluated on 4-year overall survival (p=0.215). Robotic minimally invasive mitral valve repair showed comparable 4-year survival (98.4% vs 94.4%, P=0.215) and freedom from moderate-or-greater MR (97.9% vs 98.5%, P=0.230) vs nonrobotic repair.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: