Key result
Wearable HRV monitoring during CCR diving yields ~100% analyzable data across operational phases.
Why the study?
Heart rate variability monitoring during real-world closed-circuit rebreather diving remains methodologically challenging.
Case Report (n=1)
This exploratory case report demonstrates that a single-lead wearable ECG device placed in a custom waterproof enclosure can capture >99.7% analyzable RR interval data for heart rate variability analysis during an operational military closed-circuit rebreather dive.
Wearable HRV monitoring yields high-quality data in CCR dives; hypothesis-generating for phase-related autonomic changes in military divers.
Background: Heart rate variability (HRV) monitoring during real-world closed-circuit rebreather (CCR) diving remains methodologically challenging. This exploratory case report describes phase-related HRV variations obtained from a wearable device during a military CCR dive. Methods: A trained male military diver underwent continuous monitoring with a RootiRx® single-lead wearable device placed in a custom waterproof enclosure. Three consecutive 20 min segments were analyzed: pre-dive, CCR dive, and immediate post-dive. The post-dive segment was not acquired under standardized resting conditions, and the participant continued to wear the device throughout this period. RR interval data were analyzed using Kubios HRV Scientific 4.3.0 with medium-threshold artifact correction, smoothness-prior detrending (λ = 500), and 4 Hz interpolation. Time-domain, frequency-domain, and nonlinear HRV indices were evaluated descriptively. Results: Mean heart rate was 88.1 beats/min pre-dive, 102.8 beats/min during the dive, and 86.4 beats/min post-dive. SDNN values were 35.3, 29.9, and 49.2 ms, while RMSSD values were 29.7, 24.6, and 40.3 ms, respectively. The PNS index was −1.44, −2.08, and −1.10, and the SNS index was 1.66, 2.98, and 1.26 across the three phases. LF/HF values were 1.77, 1.46, and 3.92, respectively. Automatically corrected beats represented approximately 0.34%, 0.54%, and 0.46% of beats, with effective analyzable data proportions exceeding 99.7% in all three segments. Conclusions: An analyzable RR interval series was obtained across the three operational phases in this individual recording. However, the single-subject uncontrolled design, non-standardized recording conditions, multiple confounding factors, and absence of independent underwater validation prevent causal attribution of the observed differences to immersion, CCR exposure, or autonomic adaptation. Further controlled studies using validated underwater ECG systems are required.
No takes yet. Share an insight, caveat, or question.
Moccia et al. (2026) conducted a case report in Military closed-circuit rebreather (CCR) diving (n=1). RootiRx single-lead wearable device in a custom waterproof enclosure vs. Pre-dive and immediate post-dive segments was evaluated on Time-domain, frequency-domain, and nonlinear heart rate variability (HRV) indices and data analyzability across dive phases. Wearable RootiRx HRV monitoring during a CCR dive yielded >99.7% analyzable data, with SDNN of 35.3, 29.9, and 49.2 ms across pre-dive, dive, and post-dive phases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: