Key result
Dynamic N-13 ammonia PET measures a ~4.8-fold coronary flow reserve increase with dipyridamole.
Why the study?
Conventional scintigraphic techniques are limited to qualitative assessment of regional tracer distribution, motivating the evaluation of dynamic positron emission tomography with N-13 ammonia for quantitative measurement of regional myocardial blood flow.
Does dynamic positron emission tomographic imaging with N-13 ammonia accurately quantify regional myocardial blood flow and coronary flow reserve at rest and after dipyridamole-induced vasodilation in healthy volunteers?
Observational (n=7)
Does dynamic positron emission tomographic imaging with N-13 ammonia accurately quantify regional myocardial blood flow and coronary flow reserve at rest and after dipyridamole-induced vasodilation in healthy volunteers?
Dynamic positron emission tomography using N-13 ammonia feasibly and noninvasively quantifies regional myocardial blood flow and coronary flow reserve in humans, yielding estimates in close agreement with invasive techniques.
Evaluation of regional myocardial blood flow by conventional scintigraphic techniques is limited to the qualitative assessment of regional tracer distribution. Dynamic imaging with positron emission tomography allows the quantitative delineation of myocardial tracer kinetics and, hence, the measurement of physiologic processes such as myocardial blood flow. To test this hypothesis, positron emission tomographic imaging in combination with N-13 ammonia was performed at rest and after pharmacologically induced vasodilation in seven healthy volunteers. Myocardial and blood time-activity curves derived from regions of interest over the heart and ventricular chamber were fitted using a three compartment model for N-13 ammonia, yielding rate constants for tracer uptake and retention. Myocardial blood flow (K1) averaged 88 +/- 17 ml/min per 100 g at rest and increased to 417 +/- 112 ml/min per 100 g after dipyridamole infusion (0.56 mg/kg) and handgrip exercise. The coronary reserve averaged 4.8 +/- 1.3 and was not significantly different in the septal, anterior and lateral walls of the left ventricle. Blood flow values showed only a minor dependence on the correction for blood metabolites of N-13 ammonia. These data demonstrate that quantification of regional myocardial blood flow is feasible by dynamic positron emission tomographic imaging. The observed coronary flow reserve after dipyridamole is in close agreement with the results obtained by invasive techniques, indicating accurate flow estimates over a wide range. Thus, positron emission tomography may provide accurate and noninvasive definition of the functional significance of coronary artery disease and may allow the improved selection of patients for revascularization.
No takes yet. Share an insight, caveat, or question.
Hutchins et al. (1990) conducted an observational in Healthy volunteers (myocardial blood flow evaluation) (n=7). Dynamic N-13 ammonia positron emission tomography with dipyridamole infusion and handgrip exercise vs. Resting state was evaluated on Myocardial blood flow (ml/min per 100 g) and coronary flow reserve (Coronary reserve 4.8 +/- 1.3). Dynamic N-13 ammonia PET quantified myocardial blood flow at 88±17 ml/min/100g at rest and 417±112 ml/min/100g after dipyridamole, yielding a coronary reserve of 4.8±1.3.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: