The terminal insulation of superconducting power equipment operates in environments characterized by low temperatures and large temperature gradients, making its surface flashover characteristics a critical factor that limits system reliability. In this study, a low‐temperature gradient flashover test platform was developed to investigate the flashover voltage and its underlying trends in glass‐fiber‐reinforced epoxy (GFRP) across various temperature differences (ΔT = 0–100 K). A charge migration model, previously validated in our work on trap characteristics, was employed to aid in interpreting the experimental results. The results indicate that low temperatures inherently suppress flashover; specifically, the isothermal flashover voltage at 193 K is 16.15% higher than that at 293 K. However, the introduction of a temperature gradient significantly reduces the flashover voltage. At ΔT =100 K, the flashover voltage drops to merely 75.13% of its isothermal counterpart, and the partial discharge inception voltage decreases by 24.62%. Simulation analysis reveals that this reduction is due to severe electric field distortion at the high‐voltage terminal: 80.67% of the total voltage drops within the first 2 mm, and the tangential surface electric field is amplified eightfold. These findings provide quantitative experimental data and mechanistic insight for the insulation design of superconducting terminals.