Key result
Ultra-high-resolution CT matches invasive angiography with ~74% diagnostic accuracy in complex CAD.
Why the study?
Ultra-high-resolution computed tomography (UHR-CT) and invasive coronary angiography (ICA) showed similar diagnostic performance under standardized Core Lab conditions in patients with severe calcification or stents, though non-inferiority was not formally met. Whether real-world site-level interpretation narrows or widens this diagnostic performance gap remained uncertain.
Does ultra-high-resolution computed tomography (UHR-CT) provide comparable diagnostic accuracy to invasive coronary angiography (ICA) for detecting hemodynamically significant stenosis in patients with severe coronary calcification or stents when evaluated by local site-level versus centralized Core Lab assessment?
Observational (n=173)
Blinded centralized Core Labs
Yes
Does ultra-high-resolution computed tomography (UHR-CT) provide comparable diagnostic accuracy to invasive coronary angiography (ICA) for detecting hemodynamically significant stenosis in patients with severe coronary calcification or stents when evaluated by local site-level versus centralized Core Lab assessment?
Answers are grounded in this paper and cite their sources.
In patients with severe coronary calcification or stents, UHR-CT demonstrated identical real-world diagnostic accuracy (74.0%) to invasive coronary angiography for detecting hemodynamically significant stenosis, narrowing the performance gap observed under centralized Core Lab conditions.
Background Imaging studies interpretation in clinical practice may differ substantially from centralized Core Laboratory assessment, particularly in complex patients with severe calcification or stents. In the CORE PRECISION study, ultra–high-resolution computed tomography (UHR-CT) and invasive coronary angiography (ICA) demonstrated similar diagnostic performance under standardized Core Lab conditions, although statistical non-inferiority was not formally met. Whether real-world interpretation narrows or widens this performance gap remains clinically relevant. Purpose To compare the diagnostic performance of UHR-CT and ICA to detect hemodynamically significant stenosis according to local versus centralized core lab assessment. Methods In a prospective multicenter study conducted in Brazil, Japan, and the United States, 173 patients with a calcium score ≥400, known coronary stenosis ≥ 50% or stents underwent UHR-CT prior to an invasive coronary angiography (ICA) due to suspected obstructive coronary artery disease (CAD). UHR-CT and ICA images were analyzed locally at each site and by blinded and centralized Core Labs. Stenosis ≥70% on UHR-CT or ICA were deemed obstructive, and functional significance (reference standard) was defined by an abnormal quantitative flow ratio. The diagnostic accuracy of UHR-CT and ICA for detecting significant stenosis was calculated based on both Core Lab and site-level assessments. Results Among the 173 patients (mean age 65.2 years, 72% male), obstructive CAD was present in 115 (66%). The mean calcium score in patients without stents (n=115) was 1,004 (± 1,108). In real-world site-level readings, ICA accuracy decreased from 83.2% to 74.0% (p for difference=0.009), whereas UHR-CT showed a more modest decline, from 80.3% to 74.0% (p for difference=0.04). The reduction in performance was more pronounced for ICA specificity, resulting in convergence of diagnostic accuracy between modalities in routine practice (Fig 1A). Intercontinental variability further highlighted differences between controlled Core Lab conditions and real-world interpretation (Fig 1B). Conclusion In patients with severe coronary calcification or stents, UHR-CT offered similar diagnostic accuracy to ICA in detecting patients with significant CAD. The diagnostic performance gap between UHR-CT and ICA was narrower in real-world practice than under Core Lab adjudication, suggesting that variability in routine interpretation may influence comparative effectiveness analyses and the pragmatic performance of UHR-CT may be closer to ICA than suggested by controlled trial conditions, with important implications for real-world decision-making and study design.
No takes yet. Share an insight, caveat, or question.
Matuck et al. (2026) conducted an observational in Suspected obstructive coronary artery disease with severe calcification or stents (n=173). Ultra-high-resolution computed tomography (UHR-CT) vs. Invasive coronary angiography (ICA) was evaluated on Diagnostic accuracy for detecting hemodynamically significant stenosis (≥70% stenosis with abnormal quantitative flow ratio) in real-world site-level versus Core Lab assessment (p=0.04 for UHR-CT site vs Core Lab; 0.009 for ICA site vs Core Lab). Ultra-high-resolution CT achieved identical real-world diagnostic accuracy to invasive angiography (74.0% vs 74.0%), narrowing the Core Lab gap (80.3% vs 83.2%) in heavily calcified or stented CAD.