Key result
Vasovagal syncope is linked to impaired splanchnic vasoconstriction during tilt testing, reversible by splanchnic nerve stimulation.
Why the study?
The regional fluid dynamics precipitating vasovagal syncope have not been mapped continuously across compartments, and the blood pressure dose-response relationship of greater splanchnic nerve stimulation remained undefined.
Does splanchnic pooling drive vasovagal syncope during head-up tilt testing, and does graded greater splanchnic nerve stimulation increase blood pressure in adults?
Observational (n=95)
Does splanchnic pooling drive vasovagal syncope during head-up tilt testing, and does graded greater splanchnic nerve stimulation increase blood pressure in adults?
Vasovagal syncope is driven by failure of splanchnic-to-central autotransfusion rather than excessive lower-limb pooling, and transcatheter greater splanchnic nerve stimulation elicits a dose-dependent pressor response that could serve as a targeted neuromodulation therapy.
Splanchnic autotransfusion failure may drive tilt-induced syncope; leaves open GSN stimulation as neuromodulation target.
Background Vasovagal syncope (VVS) is the most common cause of transient loss of consciousness (1), yet the regional fluid dynamics precipitating events remain poorly characterised. Splanchnic pooling has been implicated (2,3) but never mapped continuously alongside other compartments. Greater splanchnic nerve (GSN) stimulation raises blood pressure in canine models (4) and during human splanchnic activation (5), but the dose-response relationship is undefined. We used multi-segmental bioelectrical impedance analysis to map fluid shifts preceding syncope and performed graded GSN stimulation to characterise its dose-response effect on blood pressure. Methods Ninety-three adults referred for unexplained syncope underwent 70° head-up tilt testing with simultaneous three-channel BIA of thoracic, splanchnic, and thigh compartments, with beat-to-beat arterial pressure and ECG monitoring. Impedance changes were expressed as percentage change from supine baseline. In a separate substudy, two adults without syncope underwent graded percutaneous transcatheter GSN stimulation (15, 20, and 25 mA at 20 Hz) via the azygos vein during elective electrophysiology procedures with continuous invasive blood pressure monitoring. Results Fifty-six (60%) developed syncope. Systolic blood pressure diverged between groups three minutes before syncope (p=0.02). In the final four minutes, non-fainters showed a significant rise in splanchnic impedance (+1.4±0.3%, p=0.001) with stable thoracic impedance, indicating splanchnic-to-central autotransfusion. Fainters showed no splanchnic impedance change (−0.5±0.4%, p=0.09) but a thoracic impedance rise (+2.9±0.3%, p=0.02), indicating splanchnic pooling with central hypovolaemia. Thigh impedance decreased similarly in both groups. GSN stimulation produced a dose-dependent rise in systolic blood pressure (baseline 130.5 mmHg; 135.4 at 15 mA [p=0.22]; 138.5 at 20 mA [p=0.02]; 136.8 at 25 mA [p=0.01]), with no heart rate change. IVC control stimulation produced no effect. Conclusions VVS is distinguished not by excessive lower-limb pooling but by failure of splanchnic autotransfusion, resulting in central volume depletion. Graded GSN stimulation elicits a dose-dependent, heart-rate-independent pressor response, establishing splanchnic neuromodulation as a mechanism-targeted therapeutic strategy.
No takes yet. Share an insight, caveat, or question.
Zuhair et al. (2026) conducted an observational in Vasovagal syncope (n=95). 70° head-up tilt testing with multi-segmental bioelectrical impedance analysis and graded greater splanchnic nerve stimulation vs. Non-fainters (for tilt test) / Baseline and IVC control stimulation (for GSN substudy) was evaluated on Percentage change in splanchnic and thoracic bioelectrical impedance from supine baseline in the final four minutes before syncope (p=0.001). Head-up tilt testing showed fainters lacked the splanchnic impedance rise seen in non-fainters (-0.5% vs +1.4%, p=0.001) while GSN stimulation raised systolic BP to 138.5 mmHg at 20 mA (p=0.02).