Key result
Syringe-targeted Valsalva achieves ~9 percentage points greater mitral E-wave reduction vs conventional Valsalva.
Why the study?
Manometer-guided targeted Valsalva maneuvers increase setup complexity and consumable use during transthoracic echocardiography. This study evaluated a simplified, goal-driven instruction using a 10-mL syringe plunger as a motivational target.
Does a simplified syringe-targeted, goal-driven Valsalva maneuver improve maximal percent reduction in mitral E-wave velocity during strain compared to conventional manometer-guided Valsalva in patients undergoing transthoracic echocardiography?
RCT (n=51)
Randomized, within-subject crossover
Does a simplified syringe-targeted, goal-driven Valsalva maneuver improve maximal percent reduction in mitral E-wave velocity during strain compared to conventional manometer-guided Valsalva in patients undergoing transthoracic echocardiography?
A simplified 10-mL syringe-targeted Valsalva maneuver yields stronger expiratory pressure profiles, greater mitral E-wave suppression, higher rates of complete venous return interruption, and an 82.3% reduction in consumable cost compared to conventional manometer-guided Valsalva during routine transthoracic echocardiography.
Simplifies Valsalva execution in echocardiography labs with stronger pressures; extends RCT crossover evidence for goal-driven over manometer-guided methods.
Background Manometer-guided targeted Valsalva (>40 mmHg for 10 s with feedback) increases setup complexity and consumable use. We tested a simplified, goal-driven instruction using a 10-mL syringe plunger as a motivational target (maximal effort encouraged; plunger motion not required). Methods In this randomized, within-subject crossover study, 51 patients undergoing transthoracic echocardiography performed two maneuvers in randomized order: (1) conventional manometer-guided targeted Valsalva with real-time pressure feedback and (2) simplified syringe-targeted Valsalva (patients were instructed to “blow as if to push the 10-mL syringe plunger,” while expiratory pressure was recorded simultaneously via a three-way stopcock). Continuous acquisition included transmitral Doppler inflow (E and A waves), ECG, and pressure curves. The primary endpoint was maximal percent reduction in mitral E-wave velocity during strain (Edrop), defined as the maximal E-wave decrease during strain relative to the maximal baseline E-wave. Secondary endpoints were pressure-curve metrics (peak pressure, pressure–time AUC, mean effective pressure, time to peak). In a contrast subset (n=31), complete venous return interruption was assessed by agitated-saline injection after initiation of exhalation and defined as no right atrial/ventricular opacification during the strain phase. Results Baseline E-wave velocity prior to the second maneuver was higher than prior to the first (92.77±22.64 vs 89.81±22.32 cm/s; p=0.001). Exploratory period-specific analysis suggested a larger advantage in Period 2 (simplified–conventional difference 8.59 percentage points, p=0.0016). Within-method comparisons showed an Edrop increase from Period 1 to Period 2 for the simplified maneuver (Period 2–Period 1 6.49 percentage points, p=0.0165) but not for the conventional maneuver (p=0.591). For pressure metrics, the simplified maneuver generated higher peak pressure (58.1 vs 52.5 mmHg; p=0.00013), greater pressure AUC (497.8 vs 442.1 mmHg·s; p=0.0078), and higher mean effective pressure (41.2 vs 36.1 mmHg; p=0.00014), with similar time to peak pressure (3.31 vs 3.19 s; p=0.58). In the contrast subset, complete venous return interruption occurred in 15/31 (48.39%) with the simplified maneuver versus 11/31 (35.48%) with the conventional maneuver (absolute difference 12.91 percentage points). Consumable cost per test was 0.39 RMB (10-mL syringe) for the simplified method versus 2.20 RMB (suction catheter) for the conventional method (−1.81 RMB, ~82.3% lower). Conclusions A syringe-targeted, goal-driven Valsalva yields larger mitral E-wave suppression, stronger pressure profiles, higher complete interruption rate, and markedly lower cost, supporting a practical strategy to standardize Valsalva provocation in routine echocardiography.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) conducted an RCT in Patients undergoing transthoracic echocardiography (n=51). Simplified syringe-targeted, goal-driven Valsalva maneuver (using a 10-mL syringe plunger) vs. Conventional manometer-guided targeted Valsalva (>40 mmHg for 10 s with real-time pressure feedback) was evaluated on Maximal percent reduction in mitral E-wave velocity during strain (Edrop), defined as the maximal E-wave decrease during strain relative to the maximal baseline E-wave. Syringe-targeted Valsalva yielded higher peak pressure (58.1 vs 52.5 mmHg; p=0.00013) and greater Period 2 mitral E-wave reduction (+8.59 percentage points; p=0.0016) vs conventional Valsalva.