Key result
Continuous ECG monitoring after ischemic stroke is linked to ~68% higher AF detection vs sequential monitoring.
Why the study?
Current ECG monitoring for AF after unexplained ischaemic stroke is usually sequential, which may delay AF detection. Whether admission-initiated continuous ECG monitoring improves AF detection compared with conventional sequential ECG monitoring was uncertain.
Does admission-initiated continuous ECG monitoring improve atrial fibrillation detection rate compared with conventional sequential ECG monitoring in patients admitted for ischaemic stroke without known atrial fibrillation?
Observational (n=365)
Does admission-initiated continuous ECG monitoring improve atrial fibrillation detection rate compared with conventional sequential ECG monitoring in patients admitted for ischaemic stroke without known atrial fibrillation?
Admission-initiated continuous ECG monitoring combined with expedited in-hospital ILR implantation for cryptogenic stroke significantly increases atrial fibrillation detection compared to sequential monitoring, particularly within the first 6 months post-stroke.
May increase post-stroke AF detection with admission-initiated continuous monitoring; leaves open confirmation in randomized trials before practice change.
Background Current electrocardiographic monitoring for AF detection after unexplained ischemic stroke is usually sequential. This strategy may delay AF detection in the post-stroke period. Purpose The aim of this study was to assess whether admission-initiated continuous ECG monitoring improves AF detection compared with the conventional sequential ECG monitoring strategy in patients with ischaemic stroke. Methods In this pragmatic study, patients were allocated to treatment groups depending on material availability in routine clinical practice. Consecutive patients admitted for ischaemic stroke, without known AF at admission, were prospectively included. In the continuous monitoring group, Holter monitoring was started at admission and maintained throughout the aetiological workup (minimum 3 days), then patients classified as having cryptogenic stroke were proposed for in-hospital implantable loop recorder (ILR) implantation. In the sequential monitoring group, patients underwent standard stepwise monitoring (≥48-hour telemetry initiated at admission followed by 24-hour Holter monitoring; minimum 3 days total), and cryptogenic stroke patients were scheduled for ILR implantation depending on team availability. The primary endpoint was the AF detection rate. Results A total of 365 patients (35.3% women, age 63.5±14.1 years) were included; 126 (35.2%) underwent continuous monitoring and 239 sequential monitoring. Baseline characteristics and follow-up period (518±262 vs 482±265 days; p=0.21) were similar between groups. The in-hospital ECG monitoring time was longer in the continuous group compared with the sequential group (137±56 vs 118±75 hours; p=0.007). In the cryptogenic stroke patients (63 patients in continuous group; 111 patients in sequential group), ILR implantation was more frequent in the continuous monitoring group (81.0% vs 60.4%; p=0.005), with a shorter time from stroke to implantation (16±22 vs 81±75 days; p<0.001). In the overall cohort, AF documentation rate was significantly higher in the continuous monitoring group after accounting for death as a competing event (HR 1.68, 95% CI 1.01-2.80; p=0.04). The difference was driven by the first 6 months after stroke (HR 1.89, 95% CI 1.04-3.43; p=0.04), while AF documentation rates were similar beyond 6 months (HR 1.15, 95% CI 0.42-3.16; p=0.77). Conclusion Admission-initiated continuous ECG monitoring after ischaemic stroke was associated with higher AF detection rates than the conventional sequential strategy, driven mainly by increased detection within the first 6 months.
No takes yet. Share an insight, caveat, or question.
Chiuariu et al. (2026) conducted an observational in Ischemic stroke (n=365). Admission-initiated continuous ECG monitoring vs. Conventional sequential ECG monitoring was evaluated on Atrial fibrillation detection rate (HR 1.68, 95% CI 1.01-2.80, p=0.04). Admission-initiated continuous ECG monitoring after ischemic stroke increased AF detection compared with sequential monitoring (HR 1.68, 95% CI 1.01-2.80; p=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: