Key result
Small aortic annuli show similar early TAVI safety between Japanese and French cohorts.
Why the study?
A clear definition of small aortic annuli remains scarce, and previous studies have frequently applied a uniform 430 mm² cutoff without accounting for regional anatomical variations or their impact on TAVI outcomes.
Does redefining small aortic annuli (SAA) for Asian patients (<385 mm² vs <430 mm² in France) impact early safety outcomes following transcatheter aortic valve implantation (TAVI)?
Cohort (n=790)
Yes
Does redefining small aortic annuli (SAA) for Asian patients (<385 mm² vs <430 mm² in France) impact early safety outcomes following transcatheter aortic valve implantation (TAVI)?
Answers are grounded in this paper and cite their sources.
This study proposes a body-size-adjusted threshold of <385 mm² to define small aortic annuli in Asian patients undergoing TAVI and demonstrates comparable short-term safety and patient-prosthesis mismatch rates between Japanese and French cohorts.
Background Small aortic annuli (SAA) have long been recognised as a risk factor for patient-prosthesis mismatch (PPM) and a poor prognostic factor. However, while 430 mm², as analyzed by multi-detector computed tomography (MDCT), is frequently used to define SAA, a clear definition remains scarce. Furthermore, previous studies have often used the same 430 mm² definition for all individuals without considering regional variations in aortic valve anatomy. Purpose This study aimed to redefine SAA and to clarify the impact of SAA on outcomes following transcatheter aortic valve implantation (TAVI). Methods The TOTO-TAVI study included patients who underwent TAVI in a university hospital and a clinic, from March 2024 to September 2025. The primary endpoint was the early safety. A subgroup analysis was performed to identify the independent risk factors of short-term outcomes using multivariate analysis. Results A total of 790 patients (385 from Japan and 405 from France) were included. When the definition of SAA in France was less than 430 mm², 189/405 (47%) cases met the criteria for SAA. Therefore, in this study, SAA was defined as less than 385 mm² to ensure that SAA patients constituted 47 % (180/385) in Japan. Overall, Japan and France showed differences in all patient background factors, with notable variations observed in age (83.9±6.1 vs. 82.8±6.2), gender (male: 42.6 % vs. 57.8 %), body mass index (22.3±3.8 kg/m² vs. 27.3±5.1 kg/m²), STS-PROM score (6.6 [3.7-10.3] % vs. 3.5 [2.3-5.7] %), and left ventricular ejection fraction (62.0±10.7 % vs. 59.1±11.6 %). Regarding anatomical differences by MDCT, patients in Japan demonstrated smaller anatomy than those in France in the annulus, left ventricular outflow tract, sinotubular junction, sinus of valsalva, both coronary arteries height, and both femoral arteries diameter (all p<0.001). However, considering annulus-perimeter-derived diameter adjusted for height, patients in Japan showed larger than those in France (14.6±1.1 mm/m vs. 14.5±1.2 mm/m, p=0.024). The early safety was comparable between patients in Japan and in France, both overall and in the SAA group (overall: 81.3 % vs. 77.5 %, p=0.19; SAA: 76.7 % vs. 75.7 %, p=0.82). The other in-hospital outcomes, including mortality and the incidence of PPM, showed no significant differences between Japan and France, both overall and in the SAA group. For subgroup analysis, SAA was not significantly associated with independent risk factors for the early safety (odds ratio: 1.4; 95% confidence interval: 0.84-2.4, p=0.19). Conclusions Considering body size, the definition of SAA for patients in Asia should be used as less than 385 mm². Given that short-term outcomes after TAVI between Asia and France showed no significant difference, including safety endpoints and the incidence of PPM, TAVI has the potential for highly favourable results even in patients with SAA.
No takes yet. Share an insight, caveat, or question.
Iwata et al. (2026) conducted a cohort in Severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) (n=790). Small aortic annuli (SAA; <385 mm² in Japan, <430 mm² in France) vs. Normal aortic annuli or between-country comparison (Japan vs. France) was evaluated on Early safety (OR 1.4, 95% CI 0.84-2.4, p=0.19). Small aortic annuli (<385 mm² in Japan, <430 mm² in France) had comparable TAVI early safety between Japan and France (76.7% vs 75.7%, p=0.82) and were not linked to safety risk (OR 1.4; 95% CI 0.84-2.4).