Key result
M-TEER is linked to improved early hemodynamics, increasing cardiac output to ~5.8 L/min.
Why the study?
Although procedural success of mitral transcatheter edge-to-edge repair (M-TEER) is typically evaluated through echocardiography, the hemodynamic changes occurring shortly after the intervention are not well characterized.
Does mitral transcatheter edge-to-edge repair (M-TEER) improve early hemodynamic parameters (cardiac output, cardiac index, stroke volume, and systemic vascular resistance) as measured by a wearable, noninvasive chest-patch device in patients with mitral regurgitation?
Observational (n=40)
No
Does mitral transcatheter edge-to-edge repair (M-TEER) improve early hemodynamic parameters (cardiac output, cardiac index, stroke volume, and systemic vascular resistance) as measured by a wearable, noninvasive chest-patch device in patients with mitral regurgitation?
Continuous noninvasive chest-patch monitoring is feasible and demonstrates that M-TEER induces immediate beneficial hemodynamic adaptations, specifically increasing cardiac output and stroke volume while reducing systemic vascular resistance.
Answers are grounded in this paper and cite their sources.
Wearable patch monitoring detects acute hemodynamic gains after M-TEER; supports feasibility but leaves open outcome prediction in larger studies.
Background Mitral transcatheter edge-to-edge repair (M-TEER) is a well-established therapeutic intervention for mitral regurgitation in elderly patients who are considered unsuitable for surgical procedures. Although procedural success is typically evaluated through echocardiography, the hemodynamic changes occurring shortly after the intervention are not well characterized. Continuous noninvasive monitoring may offer novel insights into the early cardiovascular adaptations following M-TEER. Purpose The objective is to assess early hemodynamic changes following M-TEER by utilizing a continuous, wearable, noninvasive chest-patch device designed for multiparameter hemodynamic evaluation. Methods This single-center prospective study involved the enrollment of 40 patients undergoing M-TEER procedures between April 2024 and January 2025. Hemodynamic parameters were recorded at 15-minute intervals using wearable, noninvasive, photoplethysmography-based chest patch sensors for a minimum of 12 hours prior to and more than 24 hours following the intervention. The hemodynamic features recorded included cardiac output (CO), cardiac index (CI), stroke volume (SV), and systemic vascular resistance (SVR). Results Continuous monitoring was technically feasible in all 40 patients included in the study. The mean age of the participants was 79.1±10.3 years, with 21 patients (53%) being female. Following the M-TEER procedure, significant increases were observed in cardiac output (5.5±0.7 vs. 5.8±0.9 L/min, p=0.011), cardiac index (3.0±0.5 vs. 3.2±0.6 L/min/m², p=0.002), and stroke volume (77.0±13.8 vs. 78.0±14.3 ml, p=0.005), alongside a significant reduction in systemic vascular resistance (1398.7±332.1 vs. 1333.3±356.3 dynsec/cm5, p=0.004). Within the entire M-TEER cohort, the early increase in cardiac output varied according to the etiology of mitral regurgitation (p=0.026), with atrial secondary mitral regurgitation (90%) being more frequently observed among cardiac output responders compared to ventricular secondary mitral regurgitation (10%). Conclusions Continuous noninvasive hemodynamic monitoring following M-TEER is both feasible and indicative of procedure-specific early cardiovascular adaptations. The M-TEER procedure has been shown to elicit a beneficial hemodynamic effect, characterized by an enhancement in cardiac output and a reduction in systemic vascular resistance. Further extensive studies are required to ascertain the prognostic significance of the early hemodynamic response after M-TEER.
No takes yet. Share an insight, caveat, or question.
Hoffmann et al. (2026) conducted an observational in Mitral regurgitation (n=40). Mitral transcatheter edge-to-edge repair (M-TEER) monitored with wearable noninvasive chest-patch device vs. Pre-intervention baseline was evaluated on Early hemodynamic changes (cardiac output, cardiac index, stroke volume, systemic vascular resistance) (p=0.011). Mitral transcatheter edge-to-edge repair significantly increased cardiac output (5.5 to 5.8 L/min, p=0.011) and reduced systemic vascular resistance (1398.7 to 1333.3 dyn·sec/cm5, p=0.004).
Synapse has enriched 10 related papers. Consider them for comparative context: