Key result
Quantitative MBF confirms adequate hyperemia in ~89% of clinical non-responders during stress CMR.
Why the study?
Clinical response markers such as heart rate and blood pressure changes may not reliably reflect true myocardial hyperemia during vasodilator stress CMR. Quantitative myocardial blood flow was recently proposed in a small study as a superior marker, prompting evaluation of clinical and MBF responses in a large real-world population.
Does clinical stress marker monitoring (heart rate and systolic blood pressure changes) accurately predict adequate myocardial hyperemia as assessed by quantitative myocardial blood flow in patients undergoing vasodilator stress CMR?
Observational (n=2,247)
Does clinical stress marker monitoring (heart rate and systolic blood pressure changes) accurately predict adequate myocardial hyperemia as assessed by quantitative myocardial blood flow in patients undergoing vasodilator stress CMR?
Clinical hemodynamic markers have very low specificity for identifying true vasodilator non-responders during stress CMR, supporting the routine use of quantitative myocardial blood flow mapping to verify adequate hyperemia.
Clinical markers show low specificity for hyperemia; leaves open whether quantitative MBF mapping improves stress CMR interpretation.
Introduction Accurate detection of myocardial ischemia with vasodilator stress cardiovascular magnetic resonance imaging (S-CMR) relies on adequate hyperemia, typically induced pharmacologically with adenosine or regadenoson. Current practice guidelines recommend monitoring clinical markers (heart rate (HR) increase >10 bpm or systolic blood pressure (SBP) drop >10 mmHg) (1) as surrogate for adequate hyperemia. However, clinical response alone may not reliably reflect true myocardial hyperemia, and previous studies have shown that HR and SBP changes are rather poor surrogate markers for vasodilator-induced perfusion augmentation. Recently, a small study suggested quantitative myocardial blood flow (MBF) assessment (stress MBF ≥1.43 ml/g/min in ≥1 AHA segment) as a novel and superior marker for adequate hyperemia (2). Purpose This study aimed to assess clinical and MBF response in a large real-world population of consecutive patients undergoing vasodilator S-CMR. Methods This was a retrospective secondary analysis among 2,247 all-comer patients (age 65 ± 15, 64% male) who underwent S-CMR using either standard-dose adenosine infusion (140 µg/kg/min; n=1,577) or fixed-dose regadenoson bolus injection (400 µg; n=670). HR and SBP were recorded at rest and during vasodilator stress, and quantitative MBF was measured across all myocardial segments using automated inline pixel-wise perfusion mapping. Adequate hyperemia was defined as stress MBF ≥1.43 ml/g/min in ≥1 AHA segment as previously proposed (2). Results In the overall study population, 11% and 16% of patients undergoing adenosine and regadenoson stress CMR, respectively, were non-responders according to clinical stress criteria. Based on MBF stress criteria, overall non-responder rates were 5% for adenosine and 7% for regadenoson studies, respectively. MBF non-respondance was more frequent in clinical non-reponders as compared to clinical responders (adenosine: 9.8% vs. 4.6%, p=0.003; regadenoson: 12.5% vs. 6.5%, p=0.033). Conversely, however, MBF data confirmed adequate stress response in 88% and 90% of adenosine and regadenoson studies despite evidence of non-respondance according to clinical criteria (Figure 1). Accordingly, clinical stress criteria demonstrated high sensitivity but very low specificity for predicting adequate hyperaemia according to MBF (adenosine: sensitivity 90%, specificity 21%; regadenoson: sensitivity 85%, specificity 26%). Conclusions Clinical stress criteria do not reliably confirm adequate hyperemia during vasodilator S-CMR. While they demonstrate high sensitivity, their very low specificity indicates limited ability to identify true non-responders. Notably, the vast majority (88–90%) of clinical non-responders were adequately stressed according to quantitative MBF. These findings support the routine integration of quantitative perfusion analysis into clinical S-CMR protocols to verify adequate hyperemia.
No takes yet. Share an insight, caveat, or question.
Becker et al. (2026) conducted an observational in Suspected myocardial ischemia undergoing vasodilator stress cardiovascular magnetic resonance imaging (S-CMR) (n=2,247). Clinical stress criteria (HR increase >10 bpm or SBP drop >10 mmHg) vs. Quantitative myocardial blood flow (MBF) stress criteria (stress MBF ≥1.43 ml/g/min in ≥1 AHA segment) was evaluated on Non-responder rate for adequate hyperemia (adenosine group). Quantitative MBF confirmed adequate hyperemia in 88-90% of clinical non-responders during stress CMR, showing clinical criteria have low specificity (21-26%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: