Key result
S-ICDs show no difference in complications or infections compared with TV-ICDs in dialysis patients.
Why the study?
Subcutaneous ICDs are recommended for dialysis patients to preserve vascular access and lower infection risk, and their use now surpasses transvenous ICDs in this population. However, evidence regarding the long-term real-world safety and efficacy of S-ICDs in dialysis patients remained limited.
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation reduce overall complications and infections while preserving efficacy compared to transvenous ICDs in dialysis patients, or compared to non-dialysis S-ICD recipients?
Systematic Review (n=6,553)
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation reduce overall complications and infections while preserving efficacy compared to transvenous ICDs in dialysis patients, or compared to non-dialysis S-ICD recipients?
In dialysis patients, S-ICDs did not demonstrate lower complication or infection rates compared with transvenous ICDs during medium-term follow-up, indicating that their theoretical superiority in reducing complications remains unconfirmed despite current guideline support.
Challenges guideline preference for S-ICDs in dialysis; no complication benefit versus transvenous devices observed.
Introduction The subcutaneous ICD (S-ICD) should be considered according to current guidelines for dialysis patients for its extravascular system, by preserving and reducing vascular access complications and may lower infection risk. However, evidence regarding long-term safety and efficacy in this population remains limited. The number of dialysis patients receiving S-ICDs has now surpassed those implanted with transvenous ICDs (TV-ICDs), highlighting the need to evaluate real-world outcomes. Methods A systematic review was conducted comparing (1) S-ICD and TV-ICD outcomes in dialysis patients, and (2) S-ICD outcomes according to dialysis status (dialysis vs. non-dialysis). Searches were performed in PubMed, ClinicalTrials.gov, and Embase using the terms "defibrillation," "hemodialysis," "dialysis," and "ICD." The primary endpoints were overall complications, infections and efficacy (appropriate and inappropriate shocks). Results For comparison of S-ICD and TV-ICD outcomes in dialysis patients, 3 studies were included (n = 4,751; 2,094 S-ICD and 2,647 TV-ICD). Mean age of 62 years, 69.2% male, mean LVEF 27.4%, ischemic etiology in 64%, and primary prevention in 86.9%. The mean follow-up was 58 months. Among dialysis patients, no significant differences were found between S-ICD and TV-ICD regarding total complications (p = 0.78) or infection rates (p = 0.24) [figure 1A and 1B]. For comparison of dialysed status vs non-dialysed outcomes in S-ICD recipients, another three additional studies were analyzed (n = 1,802; 265 dialyzed, 1,537 non-dialyzed). Mean age of 55 years, mean LVEF 29.1%, ischemic etiology in 43.8%, and 74.7% had primary prevention indications, with a mean follow-up of 10.5 months. Within the S-ICD cohort, dialysis patients showed a trend toward higher overall complications, without significance (p = 0.65) as the infection risk (p = 0.57) compared with non-dialysis recipients [Figure 2A and 2B]. Regarding safety, the rate of appropriate shocks was higher in dialysis patients (p < 0.00001), while inappropriate shocks were comparable (p = 0.94) [Figure 2C and 2D]. Conclusion Despite theoretical advantages and current guideline support, in this systematic analysis the S-ICD did not demonstrate lower complication or infection rates compared with TV-ICDs in dialysis patients, during medium term follow-up. Likewise, among S-ICD recipients, dialysis status did not significantly impact safety outcomes. Device efficacy was preserved across groups. These findings suggest that while S-ICDs remain a reasonable option in dialysis patients, their superiority over transvenous systems in reducing complications has yet to be confirmed.
No takes yet. Share an insight, caveat, or question.
Magalhaes et al. (2026) conducted a systematic review in Dialysis patients and non-dialysis patients receiving implantable cardioverter-defibrillators (n=6,553). Subcutaneous implantable cardioverter-defibrillator (S-ICD) vs. Transvenous ICD (TV-ICD) in dialysis patients, or non-dialysis S-ICD recipients was evaluated on Overall complications, infections, and efficacy (appropriate and inappropriate shocks) (p=0.78). Subcutaneous ICDs in dialysis patients showed no significant difference in total complications (p=0.78) or infection rates (p=0.24) compared with transvenous ICDs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: