Key result
AI-enhanced ECG predicts cardiac damage in TAVI candidates with an AUC of ~0.99.
Why the study?
In severe AS treated with TAVI, echocardiographic staging of secondary cardiac damage is time- and resource-intensive and not universally available. Whether an AI-enhanced 12-lead ECG could reproduce multiparametric cardiac damage staging and support risk stratification was evaluated.
Does an AI-enhanced 12-lead baseline ECG accurately reproduce multiparametric echocardiographic secondary cardiac damage staging in patients with severe aortic stenosis scheduled for TAVI?
Cohort (n=368)
No
Does an AI-enhanced 12-lead baseline ECG accurately reproduce multiparametric echocardiographic secondary cardiac damage staging in patients with severe aortic stenosis scheduled for TAVI?
An AI-enhanced baseline 12-lead ECG pipeline accurately reproduces echocardiographic secondary cardiac damage staging in severe aortic stenosis patients undergoing TAVI, offering a scalable, low-cost surrogate for multiparametric imaging.
May offer a scalable ECG surrogate for echo staging in TAVI; hypothesis-generating and requires prospective validation before adoption.
Background In severe aortic stenosis (AS) treated with transcatheter aortic valve implantation (TAVI), prognosis is strongly influenced by the extent of secondary cardiac damage, but echocardiographic staging is time- and resource-intensive and not universally available. Purpose We aimed to evaluate whether an AI-enhanced 12-lead ECG could reproduce multiparametric cardiac damage staging and support risk stratification along the cardiac damage continuum. Methods In this single-centre retrospective cohort, 280 baseline ECGs from severe AS patients scheduled for TAVI at the coordinating center and 88 healthy controls (stage 0) collected from a validated publicly available dataset were analyzed using a deep-learning app-based ECG model, consisting of a modified 16-layer convolutional neural network (CNN) with residual connections, trained on >90,000 ECGs and externally validated, designed to extract quantitative digital biomarkers. Ten clinically selected biomarkers derived from this system were subsequently used as input features to train Random Forest models to predict echocardiographic secondary cardiac damage stages as binary (0 vs 1–4), three-class (0 vs 1–2 vs 3–4), and exploratory five-class (0–4) outcomes; a separate Random Forest model was developed to estimate the risk of post-TAVI permanent pacemaker implantation from baseline AI-ECG features. Performance was assessed by AUC with 95% confidence intervals, and explainability was evaluated using SHapley Additive exPlanations (SHAP) analysis. Results The binary model achieved an AUC of 0.99 (95% CI 0.99–1.00) for discriminating any cardiac damage (1–4) from stage 0. Three-class discrimination between no (0), early-to-intermediate (1–2), and advanced (3–4) damage yielded an AUC of 0.86 (95% CI 0.85–0.88), with SHAP analysis for stages 3–4 highlighting the AI-ECG biomarkers for atrial fibrillation probability and pulmonary oedema as the dominant drivers of advanced-stage assignment. In the exploratory five-class weighted model, AUC was 0.80 (95% CI 0.78–0.82), and the SHAP profile for stage 4 identified left- and right-ventricular dysfunction biomarkers as the principal contributors, consistent with the pathophysiology of end-stage biventricular damage. The dedicated pacemaker model achieved an AUC of 0.68 (95% CI 0.64–0.72). Conclusions An AI-enhanced ECG pipeline applied to a single baseline 12-lead ECG accurately reproduced echocardiographic secondary cardiac damage staging, with strong three-tier stratification that isolates high-risk stages 3–4 and biologically coherent SHAP profiles for advanced damage. These findings support AI-ECG staging as a scalable, low-cost surrogate for multiparametric imaging-based assessment of extravalvular damage in the TAVI work-up and warrant prospective multicentre validation.
No takes yet. Share an insight, caveat, or question.
Rampone et al. (2026) conducted a cohort in Severe aortic stenosis scheduled for TAVI (n=368). AI-enhanced 12-lead ECG (deep-learning CNN and Random Forest models) vs. Echocardiographic secondary cardiac damage staging was evaluated on Echocardiographic secondary cardiac damage stages (binary 0 vs 1-4; three-class 0 vs 1-2 vs 3-4; five-class 0-4) (AUC 0.99 (binary); AUC 0.86 (three-class), 95% CI 0.99-1.00). An AI-enhanced baseline 12-lead ECG model accurately predicted echocardiographic cardiac damage in TAVI patients, achieving an AUC of 0.99 (95% CI 0.99-1.00) for binary and 0.86 for 3-class staging.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: