Key result
Balloon-expandable valves show comparable 4-year mortality to self-expanding valves in TAVI, with fewer strokes.
Why the study?
Strict inclusion criteria limit the generalizability of randomized trials comparing balloon-expandable and self-expanding valves for TAVI. Contemporary large-scale real-world data were needed to assess patient selection and clinical outcomes with different valve types in routine practice.
Does TAVI with balloon-expandable valves compared to self-expanding valves improve clinical outcomes and 4-year mortality in a nationwide cohort of patients undergoing TAVI?
Cohort (n=6,922)
Yes
Does TAVI with balloon-expandable valves compared to self-expanding valves improve clinical outcomes and 4-year mortality in a nationwide cohort of patients undergoing TAVI?
In a large nationwide Dutch registry, balloon-expandable and self-expanding TAVI valves demonstrated comparable 4-year adjusted mortality and 30-day pacemaker rates, though balloon-expandable valves were associated with lower in-hospital stroke rates and higher 30-day major vascular complications.
Background As transcatheter aortic valve implantation (TAVI) expands towards younger patients, valve selection has become increasingly important for lifetime management and durability. Randomized trials demonstrated comparable mortality rates between balloon-expandable and self-expanding valves but differences in outcomes such as stroke and permanent pacemaker implantation. However, strict inclusion criteria limit their generalizability. Contemporary large-scale real-world data are therefore needed to assess patient selection and outcomes with different valve types in routine practice. Purpose The aim of this study was to characterize patients and compare clinical outcomes among those undergoing TAVI with balloon-expandable versus self-expanding valves in a large, nationwide, contemporary cohort. Methods Netherlands Heart Registration data identified patients undergoing TAVI between 2019 and 2024, excluding patients with an unknown implanted valve type and with prior aortic valve intervention. Time-to-event analysis for mortality was performed using Cox proportional hazards regression, adjusting for baseline characteristics and medical history variables associated with mortality in univariable analyses. Results A total of 6,922 patients underwent TAVI in the Netherlands between 2019 and 2024. Mean age was 79.9 ± 6.3 years, and 44.9% was female. Median Euroscore II was 3.07% (interquartile range 1.95%–4.87%). Of these, 3,522 (50.9%) patients received a self-expanding valve, while 3,400 (49.1%) received a balloon-expandable valve. Patients who received self-expanding valves were more often female, frail, and more frequently had poor mobility and dyspnea. In contrast, patients who received balloon-expandable valves more often had extracardiac arteriopathy and reduced left ventricular ejection fraction. Patients receiving balloon-expandable valves experienced stroke with neurological dysfunction during hospitalization less often than those receiving self-expanding valves (1.5% vs. 2.5%; OR 0.60; 95%CI 0.42-0.85; p=0.004). Major vascular complications within 30 days after TAVI were more frequent in patients receiving balloon-expandable valves (2.4% vs. 1.7%; OR 1.45; 95%CI 1.01-2.08; p=0.04). Need for permanent implantation at 30 days was comparable between both groups (9.9% vs. 11.3%; OR 0.86; 95%CI 0.74-1.00; p=0.05). Adjusted mortality up to 4-year follow-up was comparable between patients receiving balloon-expandable and self-expanding valves (37.6% vs. 34.7%; HRadj 1.10; 95%CI 0.99-1.23; p=0.07; Fig. 1). Conclusion In this nationwide cohort, balloon-expandable valves were more often implanted in males and patients with extracardiac arteriopathy. Major vascular complications occured more often in patients receiving balloon-expandable valves. In contrast, strokes occurred more often in patients receiving self-expanding valves. The 4-year mortality rate and need for pacemaker implantation was comparable between both groups.
No takes yet. Share an insight, caveat, or question.
Broeze et al. (2026) conducted a cohort in Patients undergoing transcatheter aortic valve implantation (TAVI) (n=6,922). Balloon-expandable valve for TAVI vs. Self-expanding valve for TAVI was evaluated on Adjusted mortality up to 4-year follow-up (HRadj 1.10, 95% CI 0.99-1.23, p=0.07). Balloon-expandable valves for TAVI had comparable 4-year adjusted mortality to self-expanding valves (37.6% vs 34.7%; HRadj 1.10; 95% CI 0.99-1.23; p=0.07), with fewer strokes (OR 0.60; p=0.004).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: