Why the study?
Advancements in echocardiography generate a tremendous amount of data, requiring workflow optimization and system interoperability to manage this information. The impact of easy-access data, orchestrated workflow, and measurement automation on efficiency and diagnostic report quality in the echocardiography department needed assessment.
Does full adoption of an orchestrated echocardiography workflow with automated measurement tools improve departmental efficiency and quality of diagnosis compared to pre-adoption workflow?
Observational (n=61,879)
No
Does full adoption of an orchestrated echocardiography workflow with automated measurement tools improve departmental efficiency and quality of diagnosis compared to pre-adoption workflow?
Implementing automated echocardiographic measurement tools and an integrated cardiovascular information system significantly reduces reporting turnaround time while increasing study volume, diagnostic measurement completeness, and sonographer efficiency in handling complex cases.
Introduction Advancements in echocardiography generate a tremendous amount of data. In order to manage this information and have an impact on patients, we must optimize the workflow by creating a fast and efficient one with interoperability among systems. The study aimed to assess the impact of easy-access data, orchestrated workflow, and measurement automation on efficiency and quality of diagnosis and reports in the echocardiography department. (Figure 1) Methods Cardiac ultrasound (EPIQ CVx/Affiniti CVx; Philips) for image acquisition; Ultrasound Workspace (TTA2.5X; Philips) for automated measurements, and IntelliSpace Cardiovascular Information System (ISCV >2.x; Philips) for accessing images/data analysis and reporting were used. Transthoracic Echocardiogram (TTE) measurements were: left ventricular end-diastolic volume (LVEDV), left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), left atrial (LA) volume, right atrial (RA) area, A wave, E wave, lateral E’ (Lat E’) wave, aortic root diameter, ascending aorta diameter, and automatic global longitudinal strain (auto-GLS). We compared the data before (G1: 2018-2019) and after (G2: 2024-2025) full adoption of ISCV and automated tools. Efficiency (median time from acquisition to final report time and time per measurement), quality of diagnosis (number of measurements that support the diagnosis), complex case management, and sonographers’ impact (comparing between periods and with physicians) were evaluated. Results A total of 61,879 TTEs were retrospectively analyzed. Our data showed a 20% increase in the number of studies (P<0.001). Regarding efficiency, a significant reduction of 7 minutes (P=0.01) in reporting time was observed after ISCV full adoption. Additionally, there was an increase (40%) in measurements supporting the diagnosis, for instance, an increase (G1:0.5%&G2:8.9% p<0.001) in auto-GLS measurements. Sonographers performed 36,426 studies (G1:14,107 vs G2:22,319; P<0.001), representing a 58% increase in their workload, and reduced their time per measurement by 30% (P<0.001) while acquiring 14 more measurements per study than physicians. Furthermore, the echocardiography unit increased its highly complex cases by 50% with sonographers doubling their complex case volume from 4,158 to 8,528 examinations (P<0.001), effectively absorbing all additional complex workload. (Figure 2) Conclusions Speeding up the echo workflow and using automated tools can reduce the time from acquisition to final report while improving diagnosis, which could increase physician-patient time and enhance the patient experience. Furthermore, sonographers have been proven key in workflow optimization as they consistently work more efficiently post-implementation.Figure 1.Workflow diagramFigure 2.
No takes yet. Share an insight, caveat, or question.
Casero et al. (2026) conducted an observational in Patients undergoing Transthoracic Echocardiogram (TTE) (n=61,879). Full adoption of IntelliSpace Cardiovascular Information System (ISCV >2.x), Ultrasound Workspace (TTA2.5X) automated measurements, and EPIQ CVx/Affiniti CVx ultrasound systems vs. Pre-adoption workflow (2018-2019) was evaluated on Workflow efficiency (median time from acquisition to final report and time per measurement) and quality of diagnosis (number of measurements supporting diagnosis, including auto-GLS) (7-minute reduction in reporting time; 40% increase in diagnostic measurements, p=0.01).