This paper investigates the influence of external wind on the combustion and flame spread behavior of flexible copper indium gallium selenide (CIGS) photovoltaic cells. Combustion experiments were conducted at a fixed inclination angle of 20° under varying wind speeds ranging from 0 to 4 m/s. Multiple diagnostic techniques, including high-speed videography, thermocouple measurements, and heat flux gauges, were employed to analyze key combustion parameters such as flame morphology, surface temperature distribution, and radiative heat flux. The results reveal a critical wind speed effect at approximately 2.5 m/s. Below this threshold, increasing wind speed significantly enhances combustion intensity. The maximum frontal flame spread rate reached 1.27 cm/s at 2.5 m/s, while the radiative heat flux increased from 71 kW/m2 to 90 kW/m2. Beyond this critical value, the flame spread rate decreased, and at 4 m/s, sustained frontal flame propagation was not maintained, with radiative heat flux dropping to 50 kW/m2. Furthermore, the flame spread rate on the rear side of the panel consistently exceeded that on the front side, peaking at 1.5 cm/s under 2.5 m/s wind conditions. This study elucidates the impact of wind speed on the combustion behavior of flexible photovoltaic cells and provides a foundation for fire safety assessments.
No takes yet. Share an insight, caveat, or question.
Lu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: