Dietary microalgae supplementation may influence the gaseous environment of poultry housing by altering nutrient utilization and manure characteristics, but continuous, treatment-level monitoring of in-pen gases remains challenging. This study combined a low-cost Internet of Things (IoT)-based multi-gas monitoring platform with a nutritional intervention to investigate treatment-associated changes in the gaseous environment of laying-hen pens receiving graded levels of dietary Chlorella supplementation. Following six weeks of dietary supplementation, three pens receiving 0% (Control), 0.25%, or 0.50% Chlorella were continuously monitored for 8 days using dedicated sensing units equipped with MQ137, MQ4, and MG811 sensors for ammonia ( NH 3 ), methane ( CH 4 ), and carbon dioxide ( CO 2 ), respectively. Each unit was interfaced with a Raspberry Pi 5 and ADS1115 analog-to-digital converter, with measurements transmitted to ThingSpeak for remote logging. Before deployment, the sensing units were co-located to establish unit-specific clean-air baselines and identify hardware faults. Sensor outputs were subsequently calibrated, quality controlled, smoothed, and aggregated into 30-min observations for analysis. Compared with the Control pen, both Chlorella -supplemented pens generally exhibited lower sensor-derived CO 2 , NH 3 , and CH 4 concentrations during the later monitoring periods. The 0.25% treatment showed the most consistent reduction in CO 2 , whereas 0.50% Chlorella generally showed the greatest reduction in CH 4 . NH 3 concentrations were also lower in the supplemented pens after the first 48-h period. Continuous monitoring additionally revealed within-day variation in NH 3 and CO 2 that was not evident from period-level summaries. The findings demonstrate the potential of low-cost edge-based sensing systems to continuously characterize poultry-house air quality and detect temporal environmental patterns associated with nutritional interventions. Such systems may support precision livestock farming by enabling scalable real-time environmental surveillance. Because only one pen was instrumented per dietary treatment and gas concentrations were estimated from low-cost sensors, the findings should be interpreted as exploratory treatment-associated patterns rather than definitive treatment effects. Replicated monitoring studies incorporating reference-grade instrumentation and environmental covariates are warranted.
No takes yet. Share an insight, caveat, or question.
Ogbuigwe et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: