Key result
Rapid-deployment sutureless valves show comparable 30-day mortality but shorter cross-clamp times vs. standard sutured prostheses.
Why the study?
Sutureless valves offer an alternative approach to aortic valve replacement, prompting a comparison of prostheses with a rapid-deployment sutureless cuff against standard sutured prostheses in patients with degenerative aortic valve disease.
Does surgical aortic valve replacement using a rapid-deployment sutureless cuff with mechanical or biological cartridges affect 30-day all-cause and prosthesis-related mortality and operative times compared to standard sutured mechanical (Medeng-2) or biological (UniLine) prostheses in adults with degenerative aortic valve disease?
Observational (n=105)
Open-label
Non-randomized
No
Does surgical aortic valve replacement using a rapid-deployment sutureless cuff with mechanical or biological cartridges affect 30-day all-cause and prosthesis-related mortality and operative times compared to standard sutured mechanical (Medeng-2) or biological (UniLine) prostheses in adults with degenerative aortic valve disease?
This prospective pilot study demonstrates that a novel rapid-deployment sutureless cuff platform accepting both mechanical and biological valve cartridges significantly reduces cardiopulmonary bypass and aortic cross-clamp times compared to standard sutured prostheses, with comparable 30-day mortality and lower discharge pressure gradients than mechanical sutured valves.
Introduction: Sutureless valves represent an alternative approach to aortic valve replacement, enabling rapid prosthesis implantation without placement of multiple interrupted sutures. Objective: To compare prostheses with a rapid-deployment sutureless cuff with standard sutured prostheses in patients with degenerative aortic valve disease. Methods: This prospective, single-centre, non-randomised pilot studyincluded 105 patients who underwent aortic valve replacement between January 2022 and March 2024. Patients were allocated to three groups: a rapid-deployment sutureless cuff with mechanical or biological valve cartridges (n = 35), the Medeng-2 mechanical prosthesis (n = 41), and the UniLine biological prosthesis (n = 29). The primary endpoints were allcause and prosthesis-related mortality within 30 days. Secondary endpoints included mean transprosthetic pressure gradients at discharge and the frequency and nature of complications. Results: The groups were comparable for most preoperative characteristics,including EuroSCORE II (p = 0.213). Statistically significant differenceswere observed in age and left ventricular ejection fraction, reflectingclinical selection rather than systematic differences in operative risk. Cardiopulmonary bypass and aortic cross-clamp times were significantlyshorter in the sutureless cuff group (p < 0.001). Thirty-day all-cause mortalitywas 8.6% (3/35) in the RDSC group, 7.3% (3/41) in the Medeng-2 group, and 3.3% (1/29) in the UniLine group (p = 0.78). Permanent pacemaker implantation rates were 8.8%, 0%, and 3.3%, respectively (p = 0.18). At discharge, mean pressure gradients were lower in the sutureless cuff group than in the mechanical prosthesis group. Conclusion: Preliminary findings from this pilot study suggest that a rapid-deployment sutureless cuff reduces operative time and provides satisfactory early haemodynamic outcomes. Further studies are required to confirm safety with respect to rare complications and to evaluate longterm outcomes. Received 18 April 2026. Revised 22 June 2026. Accepted 4 August 2026. Informed consentThe patient’s informed consent to use the records for medical purposes is obtained. FundingThe study did not have sponsorship. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev, A.A. Golubev Data collection and analysis: A.M. Osipov, M.L. Kalinina, M.B. Sukhova, E. Kurmanbek uulu, D.I. Lashmanov Statistical analysis: A.M. Osipov Drafting the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Critical revision of the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Final approval of the version to be published: all authors
No takes yet. Share an insight, caveat, or question.
ZHURKO et al. (2026) conducted an observational in Degenerative aortic valve disease (n=105). Rapid-deployment sutureless cuff (RDSC) with mechanical or biological valve cartridges vs. Standard sutured prostheses (Medeng-2 mechanical prosthesis or UniLine biological prosthesis) was evaluated on 30-day all-cause mortality (co-primary with 30-day prosthesis-related mortality, which was 0% across all groups) (p=0.78). Rapid-deployment sutureless cuff prostheses showed comparable 30-day mortality (8.6% vs 7.3% and 3.3%, p=0.78) and shorter cross-clamp times (p<0.001) compared to standard sutured valves.