Key result
HaloChord achieves 100% technical success, reducing mitral regurgitation to mild or less.
Why the study?
Current transapical expanded polytetrafluoroethylene artificial chordae systems for mitral valve repair are typically limited to single-thread implantation per delivery and remain procedurally complex. This preclinical study evaluated the feasibility, safety, and mid-term efficacy of the HaloChord® system, which delivers up to two sets of chordae per sequence.
Does transapical mitral valve repair with the HaloChord® dual-set artificial chordae system reduce mitral regurgitation and maintain mid-term stability and biocompatibility in a porcine model of acute mitral regurgitation?
Does transapical mitral valve repair with the HaloChord® dual-set artificial chordae system reduce mitral regurgitation and maintain mid-term stability and biocompatibility in a porcine model of acute mitral regurgitation?
In a porcine model of acute mitral regurgitation, the HaloChord® dual-set transapical artificial chordae system demonstrated 100% procedural feasibility, sustained reduction of mitral regurgitation to ≤1+ through 180 days, and acceptable mid-term biocompatibility.
Background Implantation of expanded polytetrafluoroethylene (ePTFE) artificial chordae is an established approach for mitral valve repair, but current transapical systems are typically limited to single-thread implantation per delivery and remain procedurally complex. This study evaluated the feasibility, safety, and mid-term efficacy of the HaloChord® system, which delivers up to two sets (four threads) of ePTFE chordae per sequence, in a porcine model of acute mitral regurgitation (MR). Methods Five adult Large White pigs (60–80 kg) underwent transapical induction of acute moderate to moderately severe MR via surgical blunt disconnection of the primary chordae tendineae attached to the P2 segment. Under beating-heart transesophageal echocardiographic (TEE) guidance, one or two suturing devices per animal were deployed with the HaloChord® system and anchored at the left ventricular apex. Animals followed a staged terminal-endpoint design (n = 1 at 30 days, n = 1 at 90 days, n = 3 at 180 days). Evaluations included serial echocardiography, clinical pathology, gross examination, and histopathological scoring per GB/T 16886.6–2022 Annex E. Results Implantation succeeded in all 5 animals; two received one suturing device (4 equivalent chordae) and three received two suturing devices (8 equivalent chordae). Suturing-device operation time was 10.5 ± 5.10 min per device; fixation-device operation time was 5.2 ± 6.14 min per cycle, with the wide fixation-time variability reflecting iterative echocardiographic length titration. MR grade was reduced from 2 + to 3 + post-modeling to ≤ 1 + immediately post-procedure and remained stable through each terminal endpoint. Vena contracta width decreased substantially and remained stable at follow-up. Gross examination confirmed stable anchoring with no detachment, rupture, or thrombus. Histopathological scoring showed a more pronounced tissue response at 30 days that moderated to predominantly moderate scores at 90 and 180 days, driven primarily by fibrosis and neovascularization rather than active inflammation. Conclusions In this porcine acute MR model, the HaloChord® system demonstrated procedural feasibility on the beating heart, effective acute MR reduction, and acceptable mid-term device stability and biocompatibility. The dual-set delivery design simplifies transapical chordal implantation, providing a foundation for clinical evaluation.
No takes yet. Share an insight, caveat, or question.
Xie et al. (2026) studied Acute moderate to moderately severe mitral regurgitation (porcine model) (n=5). HaloChord transapical ePTFE artificial chordae mitral valve repair system was evaluated on Acute technical success and reduction of mitral regurgitation grade to mild (<=1+). The HaloChord system achieved 100% (5/5) technical success in a porcine model, reducing mitral regurgitation from grade 2+-3+ to <=1+ and vena contracta width from 3.67 to 1.36 mm through 180 days.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: